31
Message
type
Display
Error code/
Warning message
Error description
Warnings
Overtemp. Ambient
Ambient temperature of electronics is too high
Overtemp. Amb.: HMI
Operating unit ambient temperature is too high
Undervoltage
Undervoltage present
Overvoltage
Overvoltage present
Force overload
max. Joining force (1000N) exceeded
Drive overload
Drive current limiting is active
Error
(Error)
Group 0001'XXXX
e.g. 00010001
Temperature problems with the electronic com-
ponents
solution: Allow the device to cool down.
Group 0002'XXXX
e.g. 00020001
Voltage problems
solution: Check voltage source
Group 0004'XXXX
e.g. 00040002
Hardware Issues
1
Group 0008'XXXX
e.g. 00080001
Temperature Sensor Issues
1
Group 0200'XXXX
e.g. 02000001
Communication Module Issues
1
Group 0400'XXXX
e.g. 04000001
Drive Issues
1
10. Warnings and error messages COMET 700
1
Take a photo of the error message and contact your Leister Service Center.
Warning and error messages are shown in the
Status display area 2 (31)
or in the
working display (29)
.
• If there is a warning, you can continue to work without restriction, even though you should find and correct the
Warning display (see Warning display (Warnings) [8.8]).
cally. The corresponding error code is immediately displayed in the