TS11/TS15, Technical Data
157
Accuracy
Beam interruptions, severe heat shimmer and moving objects within the beam path
can result in deviations of the specified accuracy. The display resolution is 0.1 mm.
Characteristics
Standard measuring
std. dev.
ISO 17123-4
Measure time,
typical [s]
Measure time,
maximum [s]
Long Range
5 mm + 2 ppm
2.5
12
Principle:
Phase measurement
Type:
Coaxial, visible red laser
Carrier wave:
658 nm
Measuring system:
System analyser basis 100 MHz - 150 MHz