Programs
TPS400-5.0.1en
Setting Station
Each coordinate computation relates to the currently
set station.
At least plan coordinates (E, N) are required for the
station. The station height can be entered if
required. The coordinates can be entered either
manually or read from the internal memory.
Known Point
1. Select a PtID stored in internal memory.
2. Input instrument height.
[OK]
Sets the station.
Set manually
1. [ENH]
Calls up manual point input
dialogue.
2. Input PtID and coordinates.
3. [SAVE]
Saves station coordinates.
Continues to the input of the instru-
ment height.
4. [OK]
Sets the station.
)
If no station was set and no application
started and if in "Meas & Rec" [ALL] or [REC] was
activated, then the last station is set as the current
station.