33
Basic Operation
•
Elevation
- The distance from the invert of the pipe to the laser beam. This
distance is set by attaching the self-centring feet for the pipe size to be laid (The
150 mm, six inch feet are standard, All other sizes are optional.) or by adjusting
the height of the piper on the Trivet Mount Assembly.
•
Line
- The position of the laser beam relative to the centreline of the pipe to be
laid. Set the line by aligning the laser beam with the next manhole.
5-TOP