6: Context sensitive help
Receiver setup: Power management
Background Information
Configure the power up and low power behaviour of the receiver according to the intended use case.
Setting Descriptions
The table below describes the settings that can be configured on the Power management page.
Boot receiver on pulse to
port
Description
Serial (P1)
Determines if the receiver powers up when a pulse is received at the serial
port (P1).
Power failure recovery
Reboot after power failure
Select the power failure recovery setting.
•
Always
After a power failure, the system will immediately start up even if
there is very low power available. This should only be selected
when the system is powered by an external main AC/DC power
source. This option is not recommended for systems powered by
batteries as it could affect a deep discharge and even destruction of
the battery.
•
Sudden loss only
After a power failure, the system only starts up again if an abrupt
power failure occurred. For example, after a short circuit or
unplugging batteries by mistake. The system will not power up
automatically following a slow loss of power such as an external
battery running flat.