218
Technical Data
)
The range on the round prism is only achievable with the upgraded distance meas-
urement. Otherwise the specifications of the CPR111 are valid (max. 1000 m). Please
refer to "5.4 Distance Measurement".
Atmospheric condi-
tions
Accuracy
Beam interruptions, severe heat shimmer and moving objects within the beam path
can result in deviations of the specified accuracy.
1:
Strong haze, visibility 5km; or strong sunlight, severe heat shimmer
2:
Light haze, visibility about 20km; or moderate sunlight, slight heat shimmer
3:
Overcast, no haze, visibility about 40km; no heat shimmer
Standard measuring
Standard deviation,
ISO 17123-4
Measure time, typical [s]
Fine
2 mm + 2 ppm
< 1
Fast
5 mm + 2 ppm
< 0.5
Tracking
5 mm + 2ppm
< 0.3
Summary of Contents for Builder M power
Page 1: ...Leica Builder User Manual Version 4 0 English...
Page 21: ...Description of the System Builder 21 3 2 Set Contents Set contents b i k l m n j c d e f g h a...
Page 69: ...Configuration Mode Builder 69...
Page 77: ...Theodolite Mode Builder 77...
Page 208: ...208 Builder Safety Directions a Laser beam b Exit for laser beam b a...
Page 213: ...Safety Directions Builder 213...
Page 233: ...Index Builder 233...