A T-Probe measurement was successful, resulting in a valid point
A T-Probe measurement was not successful, no point was created
A point acquired with the T-Probe is deleted
Note
Please note that the .wav file format allows a lot of different internal settings. T-Scan Collect
does not support all of these versions, so it may happen that certain files cannot be used or
played, although other media players can play them.
Files saved in the following format can be used in T-Scan Collect: Microsoft WAV signed 16bit
PCM format (mono or stereo, 44100 Hz or 22050 Hz).
17.10 Materials
To be able to measure various materials optimally, it might be necessary to adjust specific
parameters of the sensor. This can be achieved using the Materials editor. To open it, select
Settings
Materials
. The following dialog opens:
By default, the following predefined materials are available:
Standard
,
Shiny bright
,
Dark
and
Shiny dark
.
The predefined materials cannot be modified. However, by pressing the button
Add
you can
create new materials: a dialog asking for the name of the new material will open. After
pressing
OK
, the entries for
Exposure time
and
Reflection filter
will become active.
Press
Delete
to delete the currently selected material. Note that predefined materials cannot
be deleted.
To accept all changes and choose the currently selected material, exit the dialog by pressing
OK
, otherwise press
Cancel
.
Exposure time
The exposure time is the length of time that the camera of the line scanner will be exposed.
Adjust the exposure time to suit the object you will be measuring. Use short exposure times (in