Technical Data
SPRINTER 100/100M/200/200M
77
RS232 Port
Only for SPRINTER 100M/200M. For data output, external battery connection, external
communication data collectors, etc in GSI 8/16-format.
Internal Memory
Storage
Data Transfer
Power Supply
Battery Power
Tilt Warning Range (Electronically):
± 10'
Compensator range (Mechanically):
± 10'
Setting accuracy:
0.8" max. (Standard Deviation)
Magnetic field sensitivity:
(Line-of-sight difference in horizontal constant magnetic
field at a field strength of up 5 Gauss)
< 10"
Capacity:
up to 500 points
Program (SPRINTER 100M/200M to PC):
LGO Tools
SPRINTER 100/200:
internal battery
SPRINTER 100M/200M:
internal battery and external via RS232 port
Battery internal
AA dry cells 4 x 1.5 V
Powered via RS232 port
Nominal voltage 12 V
,
voltage range 4 - xx V
,
GEV71 car battery cable to a 12 V car battery
Current Rating
max. 300 mA