Start Up

The standard screen and buttons are shown here. 
Remember to place the 2 batteries in their respective housing units

After it starts up, you will see this main menu screen

A. Time
B. Caption
C. Title Bar
D. Screen area
E. Message bar
F. Soft keys: The main 

menu options for 
settings

G. Status Bar: Includes Battery 

status and  Level Status. 
Leveling should be done first

H. Escape button
I. Menu Icon: To start your scan 

once everything is set up.

J. Shift Button

Summary of Contents for Scan Station P16

Page 1: ...Scan Station P16 Set up and Scan Product by Leica Geosystems General set up instructions ...

Page 2: ...t to level the legs Place the bubble on one leg by moving one leg not the one your trying to move the bubble toward up or down P3 4 Move the bubble to the center circle using the leg the bubble is currently leveled with Place the scanning unit on the adapter and clamp it down p5 Remember to remove the top handle The top handle is brittle and not to be used to lift the device s full weight ...

Page 3: ...ter it starts up you will see this main menu screen A Time B Caption C Title Bar D Screen area E Message bar F Soft keys The main menu options for settings G Status Bar Includes Battery status and Level Status Leveling should be done first H Escape button I Menu Icon To start your scan once everything is set up J Shift Button ...

Page 4: ...on the ground earthquake disturbance to the ground the legs are on can bring this out of range mid scan and you will have to rescan or pick a better surface area 1 Use the Adapter under the scanner to bring the bubble as close to center as possible You want the exterior Ring to be black like this photo All other settings should not be changed refer to manual if you do ...

Page 5: ...ield of View Leave everything as is except for the Scan Mode You can choose Scan Only for just measurements Images Only for only photos Scans and Images for both We will always do both Est Time is the estimated time give or take a minute for the type of scans chosen to be completed This is the overall estimation ...

Page 6: ...solution of Scans This determines how much space between laser points at certain distances The closer the laser points the more measurements taken and more detailed image you have Essentially this is pixilation for the image The time estimate is only for the laser scans ...

Page 7: ... only for photos The settings should be automatic but the only setting to change is White Balance depending on your scene Sunny for sunny outdoor Cloudy Overcast weather Cold Light Indoor with light source Warm Light Indoor with warm light source ...

Page 8: ...Configuration 4 ms Used Camera Exposure Time Image Crtl and Filters These settings are automatic and do not require changes Leave as is ...

Page 9: ...an This setting is for the close detailed scans after the initial scan is complete This is preset and only slide it to a more detailed setting depending on the need of the scan and what is being accomplished The more detailed the setting to the right sign the better ...

Page 10: ...ct Project Name the Project the Case Number Description is the address or crime type Creator is the scan operator with badge number Device Where the scans are saved keep Internal Once stored project scans will be in this folder name on device ...

Page 11: ...hine should do 2 total revolutions First laser second scans When the scan is done you will see the screen below The monitor will also reset to the same position it was when you started the scan The more scans the more detail and less blank spaces ...

Page 12: ...Clock on the dotted square icon 2 Use the stylist to Encompass the area you want to detail scan 3 Press the play bottom 4 Scanner should automatically go to the location and scan Hit return button when done with scans ...

Reviews: