6.2
Sonde Depth
☞
For sonde depth, the locators needs to be used in conjunction with a
sonde. Refer to "5.9 How to Use the Sondes".
1.
Set the locator to the required Sonde
frequency.
0016797_001
2.
Position the locator directly over and in
line with the sonde.
☞
Ensure that the locator foot is
directly on the ground.
☞
Hold the locator upright and
take care not to move it.
0016824_001
3.
Press and hold the Depth Estimation key.
0016825_001
4.
The Sonde Depth screen displays the
measured depth.
☞
Lift the locator off the ground
by approximately 15 cm/6 in
and take a second depth read-
ing. This depth reading should
confirm the added height.
0.85
0016826_001
5.
The depth is calculated as distance to the
sonde within the pipe or duct! Take into
account allowances for the diameter of
the pipe or duct.
Note the difference between a and b!
a
)
Actual depth of the utility.
b
)
Displayed depth reading: Depth to
the sonde.
0016827_001
a
b
6.3
Depth Code Information
☞
If it is not possible to take a depth reading, a depth code is displayed
as detailed.
Taking a depth
reading
Depth Code Screens
Estimating Depth and Current of a Utility