![Leica Geosystems DD120 Series User Manual Download Page 44](http://html.mh-extra.com/html/leica-geosystems/dd120-series/dd120-series_user-manual_1873523044.webp)
6
Estimating Depth and Current of a Utility
6.1
Utility Line Depth
☞
For utility line depth, the locator needs to be used in conjunction
with a signal transmitter. Refer to "5.4 Using the Transmitter in
Induction Mode" and "5.5 Using the Transmitter in Connection
1.
Set the locator to the required Signal
Transmitter frequency.
0016819_001
2.
Position the locator directly over and at
90° to the direction of the utility.
☞
Ensure that the locator foot is
directly on the ground.
☞
Hold the locator upright and
take care not to move it.
0016820_001
3.
Press and release the Depth Estimation
key.
0016821_001
4.
The Line Depth screen displays the
measured depth.
DD130 series: The measured current
(mA) is subsequently displayed.
☞
Lift the locator off the ground
by approximately 15 cm/6 in
and take a second depth read-
ing. This depth reading should
confirm the added height.
0.50
0016822_001
5.
The depth is calculated as distance to the
centre of the utility! Allowances should
be taken into account.
Note the difference between a and b!
a
)
Actual depth of the utility.
b
)
Displayed depth reading: Depth to
the centre of the utility.
a b
0016823_001
Taking a depth
reading
44