Group 5
Transport/Start up
Page 49
JET3up
Release R1.06
5.4
Start-up Commissioning
For a safe transport some hydraulic components are supplied with transportation
protection (cable ties) and the reservoir tanks are evacuated. The following steps
have to be carried out before the initial operation
Remove the transportation protection (cable ties) (Step 1)
Fill the reservoir tank (Step 2)
Carry out the function <Filling Routine> (Step 3)
5.4.1
Remove transportation safety devices - Step 1
The pumps and valves of the hydraulic system are secured with cable ties. These
have
to be
absolutely removed.
Proceeding:
Dismantle the backplane of the hydraulic cabinet
(1)
by loosing the fixing screws
(2)
.
ATTENTION
The cable tie at the main filter (3) should not be removed!
Remove the transportation protection (cable ties).
Now attach the backplane of the hydraulic cabinet again with the according fixing
screws.