Page 270
Job Editor
Group 8
Release R1.06
JET3up
8.5.2.6
Controls - Monitoring functions
There are 4 monitoring functions available. Monitoring functions are especially
required for high printing speeds.
Figure 146 Controls - Monitoring functions
8.5.2.6.1
PrintGo monitoring
With this function is activated it is
monitored whether each Print-Go signal
is processed. If a signal can be not
processed, an error message pops up.
Example:
The PrintGo signal starts the printout.
If the next PrintGo signal occurs during
the printout an error message will pop
up.
8.5.2.6.2
StrokeGo monitoring
The signals from an encoder are called
<StrokeGo signals>.
These signals are
used for speed measurement in order to
control the print speed. A printout
consists of a number of continuous
vertical movements of the ink jet, the so
called
<Strokes>.
With the
<StrokeGo
monitoring>
activated the output of the
<Strokes>
is monitored. If the
<StrokeGo-signals>
are generated
faster than the printer can produce the
<Strokes>
, an error message will pop
up.
Example:
If the production speed and therefore
the frequency of the
<StrokeGo
signals>
is too high, stroke errors may
be caused and the following error
message pops up:
Summary of Contents for JET3 up
Page 1: ...Operating Manual V1 06 Please keep for future reference ...
Page 2: ......
Page 18: ...Page 16 Introduction Group 1 Release R1 06 JET3up ...
Page 31: ...Group 2 Safety Page 29 JET3up Release R1 06 ...
Page 37: ...Group 3 Accident prevention Page 35 JET3up Release R1 06 ...
Page 42: ...Page 40 Accident prevention Group 4 Release R1 06 JET3up ...
Page 396: ...Page 394 Appendix List of illustrations Group 12 Release R1 06 JET3up 12 4 2 Print head SK 6 ...
Page 398: ...Page 396 Appendix List of illustrations Group 12 Release R1 06 JET3up 12 4 4 Cabinet LJ ...