Page 30 of 61
5.2 Technical details
The JET Rapid Wire and the option Speed Plus are equipped with a connector for compressed air.
The connector is located on the back panel of the hydraulic cabinet.
Technical data
Maximum input pressure:
10 bar (145.035 psi)
Factory preset for the pressure control: 1,4 bar (20.305 psi)
Recommended flow:
2
l/min for JET Rapid Wire and JET Rapid Wire PI,
with stepped or beveled print head cover
2
l/min for JET Rapid with option Speed Plus
Warning
Operation is only permissible with clean, dry, oil-free and filtered compressed air
(Filtering 8
μ
m).
Using compressed air that does not meet these requirements may cause serious
damages to the print head.
Attention
Make sure that there is a permanent compressed air supply!
o
The printer does not monitor the permanent compressed air supply!
o
There will be no warning in case the permanent compressed air supply fails!
Connector for
compressed air