16
_________________________________________________________________________________
4.1.1 Platform overload indicator light
This access platform is equipped with automatic platform overload system which
prevents all boom movements in case the 230 kg safe working load is exceeded.
Should this happen, there is an audible warning signal and an indicator light up at
the control panel (Figure 5 (7)).
The booms can be operated again after the
overload has been removed from the platform.
NEVER OVERLOAD THE PLATFORM!
4.1.2 Dynamic outreach control signal light
This access platform is equipped with dynamic outreach control. Outreach
depends on the actual load on the platform.
-
Red dynamic outreach control signal light (Figure 5 (7)) will blink and an
audible sound alarm can be heard when the telescope boom is about to
reach the current maximum outreach.
-
The frequency of the blinking light as well as the audible sound will
increase as the telescopic boom closes the maximum outreach.
-
When the maximum outreach is achieved red dynamic outreach control
signal light will stay continuously on and:
-
Telescope boom movement out is prevented.
-
2
nd
boom movement down is prevented.
-
Continuous audible sound will signal that the maximum outreach is achieved.
2
nd
boom cannot be lowered before moving the telescope boom slightly in.
4.1.3 Fault light
The fault light will signal errors and faults on the equipment. Possible faults are
divided into two categories based on their severity.
When an
ERROR
occurs, the red fault light will
BLINK
.
-
Equipment can be used with extreme caution.
-
Some features are prevented.
-
If the red fault light blinks, return booms onto their transport positions,
perform daily inspection (0) and remove possible cause of the error.
-
If the problem persists, contact your Leguan dealer.
When a
FAULT
occurs, the red fault light will stay
ON continuously
.
-
Ensure neither emergency stop button is pushed down.
-
If the emergency buttons are not active, one of the safety components has failed and
prevented the use of the equipment.
-
Return booms on their transport supports, stop working with the equipment and contact your
local Leguan dealer.
Possible errors and faults can be diagnosed with a separate service display (option).