Compatible with Reach IP and Advent XT2 

 

Complies with EN 14604-2005 

 

Mains powered with 7 days battery back-up 

 

Monitored wiring 

 

Optical smoke alarm with integral sounder 

 

Alarm sound level: 85dB @ 3m 

 

Smoke alarm dimensions: 120 x 145 x 45mm (HxWxD) 

 

Wall mounted control unit with white Xenon strobe light 

 

Control unit dimensions: 165 x 105 x 50mm (HxWxD) 

 

100mm diameter under-pillow vibrating pad 

 

Test button on smoke alarm and control unit 

 

Operating Temperature: 0

o

C to +40

o

 

Telecare Transceiver: 869.2125MHz Class 1.5 

 

Low battery warning 

 

Digital Heartbeat 

 

Weight: 2048 grams total 

 

Product Code: ZXT817

 

 

 
The hard of hearing smoke alarm kit is designed for installation in 
dwellings occupied by deaf or hard of hearing people. If fire is 
detected the smoke alarm will sound a loud audible alert, the 
wall mounted control unit will flash a strong white strobe light 
(excellent for day and night time alerting) and the under-pillow 
pad will vibrate to awake the heaviest sleeper. An alarm call will 
also be transmitted to the ARC or the local Manager.

 

 
Smoke Alarm Positioning

 

The smoke alarm should be located between the sleeping area 
and the most likely source of fire e.g. the living room or kitchen.

  

The smoke alarm should be sited at least 300mm from a light 
fitting or wall, ideally as centrally as possible in the room.  
The smoke alarm should be positioned no more than 600mm 
below the highest point in the room. If positioning on the wall, 
the top of the smoke alarm must be between 150mm and 
300mm below the ceiling and at least 300mm from a wall. 
Optical smoke alarms are less prone to false alarms from cooking 
fumes and are therefore suitable for locating near kitchens. Like 
other smoke alarms they can be susceptible to nuisance alarms 
from steam and should not be placed near bathrooms.  

Refer to the Manufacturer’s 

instruction booklet for more 

information on positioning. 

 

 

Control Unit Positioning

 

The control unit should be fixed to the wall so the strobe light can 
be seen from the bed and the vibrating pad can be placed under 
the pillow. It also requires connection to the mains supply. The 
smoke alarm is hardwired with the 10m cable provided.  

 

Normal Operation

 

The red light on the smoke alarm will flash once every 40 seconds 
to indicate normal operation. The green MAINS light on the 
control unit should be on when the mains supply is connected.  

 

Alarm Condition

 

The smoke alarm will sound, the strobe light will flash and the 
pillow pad will vibrate. Check if there is a fire hazard and 

leave 

the building immediately.

  

DANGER:

 

Never ignore any alarm. If you are not certain of the 

cause, leave the building immediately. 

 

Low Battery Condition

 

The telecare transceiver module battery is self-tested once a day, 

if it’s low for 7 consecutive days a low battery condition will be 

reported once a week. The transceiver module should be 
replaced as soon as possible within 30 days. This module can be 
returned to Tynetec for battery replacement. 

 

Fault Conditions

 

If the smoke alarm chirps every 40 seconds this indicates the 
chamber is degraded and it should be replaced immediately. 
If the strobe flashes the pillow pad has been disconnected, if the 
strobe flashes and the pillow pad vibrates the smoke alarm is 
disconnected. If the unit is operating on battery power alone the 
red BATTERY light will flash and the green light will be off. 

 

 

Out of Range Notification (Reach IP)

 

The Reach IP can monitor all radio peripheral devices to 
determine whether they have been damaged or removed from 

an installation. Should the Reach IP be unable to detect a device’s 

heartbeat it will autom

atically generate a “radio out of range” 

notification. Firstly, investigate if there’s a genuine reason for the 

alert, if not, arrange for the peripheral device to be replaced 
immediately. 

The “Radio out of range timer” can be set from 30 

hours to 99999 ho

urs in Pulse CMP. “Radio supervision” can be 

disabled by unchecking the tick box associated with each 
peripheral device in Pulse CMP.

 

 

Maintenance

 

Test the smoke alarm once every month. 
Clean once every 3 months using a vacuum cleaner fitted with 
the soft brush attachment. Do not use solvents or cleaners on the 
smoke alarm as they may cause damage to the sensor, the unit 
can be wiped with a damp cloth. 
Do not paint the smoke alarm as this may block the vents and 
prevent smoke from entering the sensor. 

 

Disposal

 

Waste electrical products should not be disposed of with normal 
household waste. The smoke alarm is ideally suited for disposal 
within the waste electronic and electrical equipment (WEEE) 
recycling scheme. Please recycle where facilities exist.  
Check with your local authority or contact your supplier for 
recycling/disposal advice. 