Doc No. FM0841 issue A  Page 1  

169MHz Telecare Devices 

Carbon Monoxide Detector 

__________________________________________________________________________________________________________ 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Compatible with Reach at-home alarms, Advent xt warden call,  
Altec Response and Touchsafe Pro Nursecall systems 

 

Advanced electrochemical sensor technology 

 

85dB @ 3m sounder  

 

Indicator lights: red alarm, yellow fault & green power  

 

10 year sealed for life Lithium battery 

 

Low battery warning 

 

Test & Silence button 

 

Complies with BS EN 50291-1 & 2:2010 + A1:2012 

 

Dimensions: 95mm x 114mm x 40mm (HxWxD) 

 

Weight: 193 grams 

 

Product Code: ZXT491 

 

 

 

 

 

 

 

 

Where should Carbon Monoxide Detectors be fitted? 

Carbon Monoxide (CO) detectors should be installed in every room containing a fuel-burning appliance and every sleeping room. 

 

 
Choosing a Location 

When fitting in the same room as a fuel burning appliance the detector should be at a horizontal distance between 1 and 3m from 
the potential source, if the room has a sloped ceiling it should be at the high side of the room.  
If the detector is wall mounted, it should be at least 150mm below the ceiling and at a height greater than any door or window.  
If the detector is ceiling mounted, it should be at least 300mm away from any wall or light fitting.  
If fitted in sleeping rooms the detector should be located relatively close to the breathing zone of the occupants.  
Do not mount the detector above any source of heat or steam.  

Refer to the Manufacturer’s instruction booklet for more information on posit

ioning. 

 

Typical Tools Required 

Be careful when using step ladders 

 always face the direction you are working.  

Always make sure the correct drill bits and screwdrivers are used. 

 

How to Activate the Carbon Monoxide Detector

 

To activate the detector, remove the metal  
disabling clip by pulling it out of the back of the unit.  
Retain the disabling clip for future use.

 

 

When activated the green power light will flash  
once every 60 seconds.  

 

How to Install a Carbon Monoxide Detector 

 

Make sure you have read and understood the  
instructions on positioning the detector before starting. 

 

To mount on a wall or ceiling; push-out the screw hole  
blanking plugs in the rear with a screwdriver and  
mark the position for the drill holes.   

 

Please ensure that you use the screws and wall plugs  
provided as they were chosen specifically for use  
with this product. 

 

Alternatively, the unit can be fixed with the self-adhesive  
pads provided. Ensure the surface is smooth, clean and dry.  
Press hard to make sure the self-adhesive pads are  
properly adhered.  

 

It can also be positioned free-standing on a shelf. 
 

 
 
 
 

 