Forta LED Floodlight
Instruction Manual
Cat. No:
LFL0110WBL, LFL0120WBL,
LFL0130WBL, LFL0140WBL
1
Specification
Cat. No.
LFL0110WBL LFL0120WBL LFL0130WBL LFL0140WBL
Nominal Input Voltage
230-240 V a.c 50 Hz
Input Power
11 W
23 W
32 W
43 W
Lumens Output
730 lm
1040 lm
2250 lm
3000 lm
Colour Temperature
Cool White 4000K (Nominal)
Protection Class
Class 1
Lens/Glass
>2m (recommended)
IP Rating
IP44
Dimensions
115 x 87
x 130 mm
180 x 140
x 135 mm
228 x 188
x 175 mm
228 x 188
x 175 mm
Weight (excl.packaging)
0.6 kg
0.9 kg
1.5 kg
1.6 kg
Power cord requirement
H05RN-F 3G 1mm
2
(not included)
Fig 1
1
Lamp Cover Screw
2
Terminal Block
3
Junction Box Cover Screws (x 4pcs)
4
Wall Mounting Bracket Screws (x 2pcs)
5
Wall Mounting Bracket
6
Gland
7
Power Cable (not included)
Read all the instructions before installation. This instruction manual is to be left at the installation site. These floodlights
must be installed by a licensed electrician.
Installation
Installing a wall switch adjacent to the power source is recommended.
1. Remove mounting bracket from the fitting and use to mark position on
the wall/ceiling.
2. Mount the bracket on the wall/ceiling. Ensure the method of fixing can
support up to a 10kg weight.
3. Reattach fitting to the bracket.* Do not tighten bolts completely
to allow for mains wiring termination.
* Ensure that cord gland faces downwards in the final mounting
position (as shown in Fig.1).
N
L
Fig 2
Blue wire to Neutral
Green-Yellow to Earth
Brown wire to Switch
White wire to Light
Green-Yellow to Light
White wire to Light
4. Choose rubber-sheathed 3-core circular cord, H05RN-F 3G 1mm
2
(not supplied) for the mains wiring.
5. Remove junction box cover, strip insulation from cord and insert into
cord gland. Wire up as shown in Fig 2.
6. Replace junction box and tighten screws to ensure a weatherproof
seal. Tighten gland.
7. Orient fitting to desired position and tighten bolts completely.
7
6
5
4
3
2
1