background image

Please read carefully

Warranty

Legrand warrants the following on the Instant Heat from the date of purchase:
• 5-year warranty on materials and workmanship (excluding heat lamps and centre light).
•  2-year warranty on heat lamps and centre light. These goods come with guarantees that 

cannot be excluded under the Australian and New Zealand Consumer Laws. You are entitled 
to a replacement or a refund for a major failure and compensation for any other reasonably 
foreseeable loss or damage. You are also entitled to have the goods repaired if the goods fail 
to be acceptable quality and the failure does not amount to a major failure.

See the Warranty card enclosed with this product for further details.

Customer Service

For all Customer Service and Technical Support  
please call Monday to Friday during business hours.

Legrand Australia
1300 369 777
www.hpm.com.au

Legrand New Zealand
0800 476 009
www.hpm.co.nz

ABN: 31 000 102 661

LE12232AAA                                                              09/2020

Ducted Instant Heat 3-in-1

2 Heat Lamp model: BH2DWE 

4 Heat Lamp model: BH4DWE

Instruction Sheet

1

2

The Ducted Instant Heat 3-in-1 are ceiling mounted heat lamp appliances combining the functions of heater, extraction fan and luminaire.

Read through these instructions completely before commencing installation. Retain for future use. 

This product shall be installed by a licensed electrical contractor or similarly qualified person.

CAUTION: 

Regulations concerning the discharge of air must be fulfilled. Local building codes may require venting to the outside. The Instant Heat is 

for ceiling mounting only, with the lowest point to be at least 2.2 metres above floor level. It is not intended to be installed in wardrobes or 

within 300mm of walls. Please note there is a danger of combustion if placed too close to curtains or other flammable materials. Under no 

circumstances must the Instant Heat be covered with insulating material within the ceiling space.  

Instant Heat must not be installed where there is a possibility of water splashing on to the lamps. Locate in accordance with the  

requirements of the Wiring Rules AS/NZS 3000 relating to damp situations. This means that no part may be located directly above any part 

of the bath or shower recess or enclosure. For unenclosed showers refer to the Wiring Rules conditions.

Note:

  Steam  will  only  be  removed  if  there  is  sufficient  flow  of  air  through  the  room.  Ensure  adequate  inlet  openings  in  the  room  are                                   

           provided, for example through windows, vents or under the door. Air-flow paths from room inlets to fan should ideally pass over   
           surfaces where condensation may form.

Product Notes

Trouble shooting

1.  This product must be installed and used as per these instructions.
2.   A switch disconnection must be incorporated in the fixed wiring in accordance with the wiring rules.
3.   This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack 

of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person 

responsible for their safety. Children should be supervised to ensure that they do not play with the appliance.

4.   This appliance is intended for household use and similar purposes. It is not suitable for use in an environment heavily laden with dust. 

Under these conditions the life of the fan motor can be significantly reduced.

5.   This product contains no serviceable parts and no attempt should be made to repair this product. If the product is faulty it should be 

discarded.

6.   This product must be cleaned periodically from dust and other contaminants with a damp cloth. Aggressive cleaning agents and 
       solvents should never be used.
7.   Airflows listed in this instruction sheet indicate the product performance. Refer to the BCA (Building Code of Australia), or similar, 
       for the appropriate airflow required for a particular installation.
8.   Ventilation products must have an adequate source of external air to ensure correct performance.
9.  This product should not be enclosed in thermal insulation as it may cause the unit to overheat.
10.  This product has been designed for domestic or similar uses and is not suitable for a commercial installation.
11.   Precautions must be taken to avoid the back-flow of gases into the room from the open flue of gas or other fuel-burning appliances.
12.   Extended exposure to UV rays (such as exposure to direct sunlight) may cause discolouration of this product.
13.   This product is not suitable for installation in hazardous and/or corrosive areas.
14.   This product has been designed to operate in ambient temperatures 5°C to 40°C.
15.   The material in this product may vary in colour from batch to batch. Colour matching from one batch to another cannot be guaranteed.
16.    This product utilises intellectual property in the form of registered designs, trademarks, and/or patents. Such intellectual property  
         remains the property of  Legrand in all cases.

This Instant Heat is fitted with a thermal cut-out to provide over-temperature protection. If the heat lamps begin to switch ON/OFF 

intermittently this may indicate the unit was wired incorrectly, allowing the lamps to operate without the fan running. To rectify please 

check your installation.

BH2D

BH4D

  Box contents

BH2D

BH4D

Housing

1 piece

1 piece

Infrared Heat Lamps (275W)

2 pieces

4 pieces

Light globe (7W LED)

1 piece

1 piece

Instruction Sheet

1 piece

1 piece

Warranty card

1 piece

1 piece

Hole-cutting template

1 piece

1 piece

Ducting (3m x Φ150mm)

1 piece

1 piece

Duct holder

1 piece

1 piece

External grille

1 piece

1 piece

Wall switch plate

1 set

1 set

Duct tape and cable ties

1 set

1 set

5

1

4

 

 Specifications

# - measured with 3 m and Φ150 mm ducting.

Note:

 Airflow will be reduced with bends in duct, squashing of duct, restrictions on replacement air entering the room to be ventilated, 

                    or  pressure  differentials  between  the  room  and  outside  air  and  elevation  of  the  outlet  duct  and  grille  with  reference  to  the                                

          bathroom heater.

Model:

BH2D

BH4D

Supply voltage:

230-240 V a.c.  50 Hz

Max. power rating:

840 W max

1570 W max

Airflow#:

180 m

3

/hr max

Ceiling cut-out:

205 x 395 mm

295 x 355 mm

Projection into ceiling:

205 mm

Required ceiling depth:

300 mm

Fascia

Size

440 x 250 mm

400 x 340 mm

Protrusion (excl. lamps)

23 mm

Heat lamps provided:

2 x 275 W

4 x 275 W

Thermal overload protection:

100° C

Draught stopper:

Yes

Centre Light provided:

7W LED R80 E27

Weight (excl packaging):

4.3 kg

5.2 kg

Reviews: