Non-ducted heater, exhaust fan and LED light

Specification

Supply Voltage:  
Frequency:

230-240 V a.c.

50 Hz

Max. Power Consumption: 1240 W
(May be connected to a light or power circuit if loading permits.)

Please read carefully

Read through these instructions completely before commencing

installation.

CAUTION

This product is not designed to be ducted. Do not fit after-market ducting 
kits. If ducting is required, then the ducted Instant Heat series, 

R622D2 

is

more suitable for this purpose.
Regulations concerning the discharge of air have to be fulfilled. Local 
building codes may require venting to the outside. The volume of the roof  
space must be a minimum of 3 cubic metres and adequately ventilated to  
allow moisture to dissipate.
This product is to be installed in standard roof applications only, not in 
restricted ceiling cavities as found in multi-storey applications (See Fig. 1)

Installation:

The infrared lamps heat by direct radiation rather than by heating the air in 
the room, so the Instant Heat should be located directly over the drying area.
HPM Instant Heat must not be installed where there is a possibility of water  
splashing on to the lamps. Locate in accordance with the requirements of  
the Australian/New Zealand Wiring Rules AS/NZS 3000 relating to damp 
situations. This means that no part may be located directly above any part 
of the bath or shower recess or enclosure. For unenclosed showers refer to  
Wiring Rules conditions.
Note: Steam will only be removed if there is sufficient flow of air through the 
room. Ensure adequate inlets exist through windows, vents or under the door.  
Air-flow path from inlets to fan should ideally pass over the steam sources.

Location:

The Instant Heat is for ceiling mounting only, 
with the lowest point to be at least 2.2  metres 
above floor level. It is not intended to be 
installed in wardrobes or within 300mm of 
sides of walls, as per Figure 2. There is a 
danger of combustion if placed too close to  
curtains or other flammable materials.
Note: Instant Heat products must only be
installed horizontally in ceiling.

Ceiling preparation:

Instant Heat may be installed either between  
joists using the built-in clip fasteners or 
against a joist using a screw to replace a clip. 
Drill a hole in the flange to suit.
The clearances between Instant Heat and  
adjacent building members shown in Figure 3  
shall be observed. Thermal insulation or similar 
material shall not be placed on top of the unit,  
and adjacent material to the side shall be kept  
clear to a minimum distance of 200mm (Fig.4).
Joists, beams and rafters shall not be cut or  
notched to install Instant Heat.
After determining the location of Instant Heat  
use this template to mark out and cut the 
aperture (Fig 5). If adequate support is not  
available for Instant Heat, it may be necessary to 
provide extra strengthening.

Fixing to ceiling:

Remove all lamps to prevent damage from clip

fasteners. Spin the fan to check for freedom of rotation. Push the Instant  
Heat body into the opening allowing the springs to snap open. To secure, 
push the lower ends of the springs apart (Fig. 6). Ceiling board thickness  
should be adjusted to enable the springs to be fitted without excessive force.

Final assembly:

Check that the power to the unit is off. Position 
the lamp surround below the unit so that the two 
pins  on the underside line up with the two holes 
in the flange. The cover is designed to snap onto 
the housing flange (Fig. 7) which sits flush 
against the ceiling.
Insert the five lamps into the sockets, tightening 
well to ensure good electrical contact and long 
life. Wipe the surround and the bulbs clean.
Connect the power and check all functions.

Wiring:

Four switches on an Excel Life wall plate are 
supplied. Do not use with any solid state speed  
control. Wall plate should be located so that the  
switches are not within reach of a person in a  
bath or a shower. Wiring connection is as per 
Figure 8.

Please use this card as hole cutting template 322mm x 322mm

Instant Heat 3-in-1

Non-Ducted 4 Heat Lamps

Cat.No. BH4NDWE / BH4NDMS

Instruction Manual

Fig8. Wiring diagram

Fig 5

Fig 6

Fig 7

Fig 1

Fig 4

›200mm

›200mm

Fig 2

Wall

>300mm

>300mm

Fig 3

300mm

Min. clearance

Unobstructed  

Airflow

500mm Min.

2.2M Min.

This product should be installed by a licensed electrician or similarly qualified person.

Note: The fan will run automatically when the    

heat lamp is switched ON.

CAUTION: Warranty will be void if the instant    

heat unit is not wired as per wiring 

diagram (Fig.8) below.

H

H

H

Inst ant  Heat
Cat .No. BH4ND

Earth

Neutral

Light

Fan

Heat 1

Heat 2

Excel Life

Switch Plate