background image

1/8

Technical data sheet: S000074405EN-2 

Updated: 10/02/2016 

Created: 18/01/2013

Catalogue Number(s): 0 488 04

PIR switch sensor 

  1. USE

This device allows a light source to be controlled automatically through 

the detection of movement in the surveillance zone.

It is equipped with a "presence" output for ventilation or lighting 

control. This output is separate from the level of light.

Motion sensor with 360° detection angle.

Detection type: infrared (PIR)

Mounting type: ceiling 

  2. TECHNICAL CHARACTERISTICS

Voltage: 100 - 240 V~

Frequency: 50/60 Hz

No-load power consumption: 0.8 W

Output via normally open contact connected to the phase

Wiring: 2 x 2.5 mm

2

Drilling diameter:  85 mm without flush-mounting box   

85 mm with flush-mounting box

Weight: 114 g

Impact resistance: IK04

Penetration by solid and liquid matter: IP20 (unmounted)

 

 

 

             IP41 (mounted)

Usage temperature: - 5°C to + 45°C

Storage temperature: - 20°C to + 70°C

   2.  TECHNICAL CHARACTERISTICS (continued)

Cover removed

CONTENTS Page

1. Use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1

2. Technical characteristics  . . . . . . . . . . . . . . . .1

3. Dimensions. . . . . . . . . . . . . . . . . . . . . . . . . . . . .2

4. Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2

5. Installation  . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4

6. Removal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4

7. Operation  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5

8. Settings  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6

9. Performance . . . . . . . . . . . . . . . . . .   . . . . . . . .7

10. Care . . . . . . . . . . . . . . . . . . . . .   . . . . . . . . . . . . .8

11. Standards and approvals . . . . . . . . . . . . . . . .8

12. Troubleshooting  . . . . . . . . . . . . . . . . . . . . . . . .8

1 - Halogen bulb
2 -  ELV halogen bulb with separate electronic ballast
3 -  ELV halogen bulb with separate ferromagnetic ballast
4 - Fluorescent tube with separate ferromagnetic ballast
5 -   ELV fluorescent tube with separate electronic ballast
6 -  Compact fluorescent bulb with built-in electronic ballast
7 -  Compact fluorescent bulb with separate ferromagnetic ballast
8 - Compact fluorescent bulb with separate electronic ballast
9 - LED bulb
10 - Contactor
11 - Motor

230 V~ 2000 W

8.5 A

1000 VA

4.3 A

10x(2x36 W)

4.3 A

500 VA

2.1 A

1000 VA

4.3 A

500 VA

2.1 A I max. ≤ 2A

110 V~ 1000 W

500 VA

5x(2x36 W)

250 VA

500 VA

250 VA

1

2

3

4

5

6

7

8

9

LEARN button

LEARN LED 

Green 

programming 

indicator

IR transmission LED  

(for configuration 

tool)

Sensor/PIR 

sensor

IR receiver LED  

(for configuration 

tool or remote 

control)

Protective cover

Green 

detection 

indicator

Light level cell

230 V~

2000 W

8.5 A

I max. ≤ 2A

110 V~

1000 W

U ≤ 30 V

=

2 A max.

Summary of Contents for 0 488 04

Page 1: ...er removed CONTENTS Page 1 Use 1 2 Technical characteristics 1 3 Dimensions 2 4 Connection 2 5 Installation 4 6 Removal 4 7 Operation 5 8 Settings 6 9 Performance 7 10 Care 8 11 Standards and approvals 8 12 Troubleshooting 8 1 Halogen bulb 2 ELV halogen bulb with separate electronic ballast 3 ELV halogen bulb with separate ferromagnetic ballast 4 Fluorescent tube with separate ferromagnetic ballas...

Page 2: ...h sensor 3 DIMENSIONS Without protective cover 4 CONNECTION Number of terminals 6 Type of terminals automatic Terminal capacity 2 x 2 5 mm2 Stripping length 8 mm 4 1 Wiring with auxiliary control 100 m max With protective cover 8 5 A 8 5 A 71 73 Ø 1 0 5 66 72 62 Ø 1 0 5 2 A 2 A U 30V Ext supply L1 L1 PB 230 110 DC VAC Wiring ...

Page 3: ... Created 18 01 2013 Catalogue Number s 0 488 04 PIR switch sensor 4 CONNECTION continued 4 2 Wiring for a single load connected in parallel 2 A SN SN LN S2 S2 L2 S1 S1 L1 PB 8 5 A 100 m 8 5 A 8 5 A 2 A L PB 8 5 A 100 m 4 3 Wiring for several loads connected in parallel ...

Page 4: ...4405EN 2 Updated 10 02 2016 Created 18 01 2013 Catalogue Number s 0 488 04 PIR switch sensor 5 INSTALLATION 1 2 3 1 2 50 Ø 85 Ø 85 0 3 to 20 mm 5 INSTALLATION continued 5 1 Sensor positioning 5 2 Recommended light exposure 4 m 2 5 m 6 REMOVAL ...

Page 5: ...time delay or when the light level threshold has been reached Auto ON OFF mode The load will be switched on and off automatically Option It is possible to control the sensor by infrared remote control using Cat Nos 0 882 00 01 20 31 32 33 7 1 More than one sensor and more than one load The products can be synchronised in two steps one long press 1s all the sensors S change to ON one short press al...

Page 6: ...5 Time delay 15 min 3 5 10 15 20 min 0 59 min 59 s Sensitivity PIR very high Low medium high very high Modes Auto on Auto off Inactive Activate Deactivate Walk through mode Active Activate Deactivate Manual on Auto off Inactive Activate Deactivate Detection system Initial PIR Non modifiable Maintain PIR Non modifiable Restart PIR PIR Deactivate Alarm Inactive Activate Deactivate 8 SETTINGS continu...

Page 7: ... Height m 2 5 4 6 3 5 5 6 5 4 6 5 7 5 5 6 10 5 6 4 5 5 Sensitivity High 75 Sensitivity Very high 100 Ø m Ø m Height m 2 5 6 5 8 3 8 5 11 5 4 12 5 14 5 12 16 5 6 8 5 12 5 Height Ø 1 2 m m 2 5 0 2 5 PIR PIR 9 PERFORMANCE continued 9 2 Presence Sensitivity Low 25 Sensitivity Medium 50 Ø m Ø m Height m 2 5 2 5 4 3 3 5 4 4 4 5 5 4 6 5 6 2 5 3 5 Sensitivity High 75 Sensitivity Very high 100 Ø m Ø m Heig...

Page 8: ...ce still continues move the sensor away from the source s of interference Lighting does not switch off during the day when there is an adequate level of natural light Regulation function not active Light level threshold set too high Light contribution too high Activate the regulation function Reduce the light level threshold Check that the sensor is positioned correctly in relation to the window D...

Reviews: