Legend 90/230 LED Installation And Operation Manual Download Page 1

®

r

G ee

U

D

lin

A

e

 

B

INSTALLATION AND OPERATION MANUAL

A joint government and in

dustry program

Legend Eco Touch VS LED

ENERGY

RATING

Energy consumption

kWh per year

To pump 50,000 litres/day

415

When tested in accordance with AS 5102.2.

Actual energy use and running costs will depend on how you use the appliance.

Compare models at www.energyrating.gov.au

Efficiency

 

L/Wh

43.9

Flow Rate

 

L/min

125 

Head

m

2.8

Power

W

171

Noise

dBA

-

LED

Summary of Contents for 90/230 LED

Page 1: ...VS LED ENERGY RATING Energy consumption kWh per year To pump 50 000 litres day 415 When tested in accordance withAS 5102 2 Actual energy use and running costs will depend on how you use the appliance Compare models at www energyrating gov au Efficiency L Wh 43 9 Flow Rate L min 125 Head m 2 8 Power W 171 Noise dBA LED ...

Page 2: ...TION 4 5 0 ELECTRICAL CONNECTION 5 6 0 PUMP OPERATION 5 6 1 GENERAL START UP GUIDE 5 6 2 LEGEND LED SPECK ECO TOUCH VS LED PUMP OPERATION 6 6 3 LEGEND LED SPECK VS PUMP CUSTOM SPEED SETTING 6 7 0 SERVICE AND MAINTENANCE 7 8 0 TROUBLESHOOTING 9 8 1 GENERAL PUMP TROUBLESHOOTING 9 8 2 LEGEND LED SPECK VS PUMP TROUBLESHOOTING 9 9 0 WARRANTY 10 9 1 TERMS OF EXPRESS WARRANTY 10 9 2 EXCLUSIONS 11 9 3 LIM...

Page 3: ...f compartment is not secure Dispose of used button batteries immediately and safely A qualified technician should carry out the pump installation Always wear protective clothing and gloves when handling adhesives The pump must be installed and operated in accordance with national wiring rules Children should be supervised to ensure they do not play with the appliance If the power supply cord is da...

Page 4: ...ne or other flammable gases or liquids in the vicinity of this pump DO NOT store pool chemicals near the pump Flooding or moisture within the motor voids warranty Please ensure the pump is elevated and kept dry 4 0 PLUMBING CONNECTION The piping should be as direct and free from turns or bends as possible as elbows and other fittings can greatly increase friction losses If the pump is located belo...

Page 5: ...l pebbles are ingested into the pump as this voids the warranty The filter should be checked for proper installation verifying that all connections are secure according to the manufacturer s recommendations a Depending on the location of the pump please do one of the following b If the pump is located below the water level of the pool open the filter pressure valve to prime the pump with water If ...

Page 6: ...ures NOTE To achieve maximum 8 star energy efficiency this setting can be adjusted down to 1450 rpm however as noted above this may not be practicable for all pool applications The Legend LED Speck VS Pump will automatically start at high speed for five 5 minutes to ensure it primes completely The pump will take a short time to prime and then deliver at full rate No further priming should be requi...

Page 7: ...l when not in use III Check for leakages Carry out weekly inspections for example a Around the pump filter chlorinator and heater where fitted where water can leak from all or some of these components b If water is present whether you can see the source of the leak or not then contact your pool retailer or your pool service technician immediately This may reduce the possibility of major pump damag...

Page 8: ...ut of the bottom of the lid f Exchange the batteries 2 x type CR2032 3V Observe the pole g Re assemble in reverse order 1 2 W90 04 100 P It is essential that the pump be operated after carrying out the above steps this will purge any air from the system Start the pump and wait until the strainer basket is full of water Then where fitted open air bleed fitting on the filter to expel air Once the st...

Page 9: ...pin freely If not repair by an authorised repairer is required 3 Low flow A Dirty Filter Backwash filter or clean cartridges B Suction leak See problem 1 above 8 2 LEGEND LED SPECK VS PUMP TROUBLESHOOTING The Legend LED Speck VS Pump has an LED Error light on the control panel which flashes to indicate a warning If the Error light is flashing pay attention to the number of flashes between interval...

Page 10: ...e Express Warranty In no event shall Legend Products Services be accountable for consequential loss or damage resulting from the breach of any Express Warranties Under Applicable Laws you may have different or additional legal rights including longer warranty periods which vary from jurisdiction to jurisdiction Some jurisdictions do not allow certain limitations on how long an implied warranty las...

Page 11: ... to storm flood and or heat wave damage Failure of the mechanical seal due to insufficient water flow caused by any blockage or ingress of foreign matter of any kind whatsoever Damage to the product caused by the addition of chemicals salt filter media or any other thing through the skimmer box Failures or any defects in component part or operating function of the product which is in the opinion o...

Page 12: ...epaid as soon as the purchaser becomes aware of any fault Neither Legend Products Services nor the approved Legend Products stockist shall be responsible for any goods damaged in transit If the equipment is found to be defective after examination it will be repaired or replaced free of charge and returned freight collect If the equipment is not defective and outside of warranty all repair or repla...

Reviews: