6
Adjusting the Volume
1. Using the remote, press the
VOLUME-
or
to increase
or decrease the volume.
2. Press the
MUTE
button to temporarily turn off all sound.
To restore the sound, press the
MUTE
button again.
Selecting the input source
1. Using the remote, press the desired source
button (VGA, HDMI 1, HDMI 2, DVI, Display-
Port, Composite Video, S-Video, Component)
2. Or press
SOURCE
on the monitor keypad,
use the arrow buttons (
) to navigate
to the desired input source, and press
ENTER
:
HDMI 1
HDMI 2
VGA
Component
S-Video
Composite Video
DVI
DisplayPort
3. If the monitor cannot find a source, a
“No signal” message will appear.
Touch Operation
No calibration is required for first-time use. However, the touch
panel might be required for calibration over time depending
on the usage. Please find calibration instructions below for the
different operating systems:
Installation:
1. Connect the signal cable to the monitor and then turn
on the monitor
2. Connect one side of the USB cable (type-B USB connector)
on the monitor side (see "Chapter 3, Signal Source Input"
for exact location)
3. Connect the other side of the USB cable (type-A USB connector)
to the computer
4. Turn the computer on
5. Once the USB cable is connected, please wait for 5 seconds
before the touch function is ready to go. It can be achieved by
using a pen, finger or any other pointer. Touch function is plug
& play: no driver is required. Please do not use landscape-type
touch monitor in portrait mode, and vice versa
Windows 7: 16 Point Calibration Procedure
1. Start USB configuration program on the computer
2. Press "Calibrate"
3. Wait for the beep. The cursor will move to the upper
left-hand corner of the screen automatically
4. Place your finger, gloved hand or any other pointer on the
cursor and hold it there for 2 seconds (a beep will be heard
when the pointer is placed on the cursor)
5. The cursor will then move to the next calibration point.
Repeat action 4. After the beep, the cursor will move to the
next calibration point
6. Repeat action 4 until you get to the last calibration point in
the lower right-hand corner
7. Complete the calibration by tapping anywhere between the
16 points. The calibration process now is complete and the
touch monitor is ready to be used
MAC OS X V10.4 & above Calibration Procedure:
To operate with an Apple MAC computer, download the driver
through link below:
http://www.nextwindow.com/nextwindow_support/
Touch_Screen_Calibration_for_Mac.html
Follow the steps given in the installation procedure and calibrate
the e-Screen
Touch operation Linux-based (2.6X & above) operating systems
For calibration see: http://www.freedesktop.org/wiki/Software/
xinput_calibrator and configure the e-Screen