www.legalett.com
Operating voltage ...............................1 P - 230V 60Hz
Output, electrical.......................................... 4 x 1000W
Fan motor power consumption ............................165W
Air flow w 8- 100 mm/4" pipe .....
≥
900 m
3
/h (530 CFM)
Air flow w 20 - 50 mm/2" pipe ...
≥
750 m
3
/h (440 CFM)
Breaker rating (GFI recommended)........................ 30A
TECHNICAL DATA
FUNCTION
1 P - 230V 60Hz
thermostat 1-4
30A circuit breaker
The 4000E heating-unit is installed in the foundation slab
or intermediate floor, and contains a fan and four heating
elements, with contactors that are controlled by 1 - 4
external electric room thermostats. It is used together
This data is generic. Each Legalett installation is unique.
Refer to customized specifications on your installation
design drawing for actual design parameters.
The 4000E is controlled by one (single zone) to four
(quad zone) external electric room thermostats. These
external thermostats operate the contactors in the unit,
energizing the heating coil and fan when the room needs
heat. The unit is also equipped with seven overheating
protection devices.
When controlled by a programmable thermostat, the
4000E can use two-tiered energy rates for night storage of
less expensive energy in the LEGALETT heated floor.
with heating unit box 4000A 100/100 (100 mm / 4" spiral
pipes) or with heating unit box 4000A 50/50 (50 mm / 2"
plastic pipes).
January, 2006
Form № 0528
Page 1 of 2
HEATING UNIT - 4000E