Page 1: ...INSTALLATION OPERATING MAINTENANCE INSTRUCTIONS R1 4016 LEVER WALL MOUNTED 3 HOLE BASIN MIXER ROUGH TO SUIT M2 1111 M2 1113 ...
Page 2: ...2 RQWHQWV Dimensions 3 InstalLation Procedure 4 Parts List 6 Fault Finder 7 Safety Tips Care and Maintenance 8 Guarantee 9 ...
Page 3: ...39mm 140mm 202mm 101mm Ø15mm 92mm 172mm 115mm 131mm 52 44mm 87 5mm Protective Cap Protective Cap Protective Cap 3 LPHQVLRQV in Inches Millimetres Whilst every effort is made to ensure accuracy design and dimensions are subject to change without notice as part of the company s product development process ...
Page 4: ...DWLRQ 3URFHGXUH Lefroy Brooks always recommends that plumbing products be installed by a licensed professional Shut off main water supply before installation 1 Before installation make sure that the 2 distance between rough and wall is as indicated in the above figure 2 Install valve body onto internal wall ...
Page 5: ...WDOODWLRQ 3URFHGXUH Lefroy Brooks always recommends that plumbing products be installed by a licensed professional Shut off main water supply before installation 3 Connect the inlets with water supply Step 3 ...
Page 6: ...tridge H 507071W 4 Back plate 126671 S 5 Screw 008013 6 Protective cap 038007 7 O ring 004026N 8 Adaptor 067732W 9 O ring 004010N 10 Cartridge C 507072W 11 Body 002727W 12 Protective cap 045160 11 10 2 8 9 7 1 4 5 12 6 3 6 3DUWV LVW Exploded view ...
Page 7: ...se Rectification Drips from spout Gasket is misfitted or damaged Check for gasket placement Leaks around handle Cartridge has come loose or damaged Tighten reinstall the cartridge or replacement the cartridge if it is damaged ...
Page 8: ... in water pressure between hot and cold supplies to the mixing valve the pressures should be equalized by a plumber in accordance with best practice and legislation Maintenance Your new bathroom faucet is designed for years of trouble free performance Keep it looking new by cleaning it periodically with a soft cloth Avoid abrasive cleaners wire wool and harsh chemicals as these will dull the finish...
Page 9: ... them to be free of design and production faults at the time of delivery and that with correct use and care in accordance with our printed instructions they will function reliably Guarantee period The guarantee is valid in private homes for 5 years from the purchase date Proof of purchase has to be provided when making a guarantee claim By use in commercial or institutional applications the guaran...
Page 10: ...ts are protected by law and the use or reproduction outside the terms of an agreement is prohibited The right to modify designs and dimensions is reserved Christo Lefroy Brooks is a member of ACID Anti Copying in Design LEFROY BROOKS INC 1828 TROUTMAN STREET RIDGEWOOD NY 11385 TELEPHONE 718 302 5292 FAX 718 302 4177 COPYRIGHT LBIP LTD 2013 718 302 5292 www lefroybrooks com ...