RMPM2T-1

TECHNICAL DATA

Rio Rancho, NM, USA

www.lectrosonics.com

 

Installing One M2T into a Single Rack 

The M2T transmitter occupies a half rack space. This 

kit provides the hardware needed to mount one M2T or 

DSQD into a single rack space.

NOTE: Steps 1-6 will require original mounting 

hardware that came with the units. Part numbers 

are included in case individual items need to be 

reordered.

1. Remove the Trim Cap (Part #P1330) from both 

sides of the front panel of the M2T unit to be  

rack mounted.

2. Remove the breakaway tabs on both sides of the 

Chassis Cover Panel. This requires the use of a 

flat-blade screwdriver inserted into the slots and 

levering the tabs away on each side of the unit.

3. Insert the Flange Bracket (Part #27076) into the 

open slot in the left-front side of the Chassis  

Cover Panel.

4. Insert two (2) Cap Screws (Part #28885) through 

the Rack Handle (Part #27082) holes and install 

the Rack Handle onto the Flange Bracket through 

the holes in the unit’s front panel. Firmly tighten 

the Cap Screws using the long leg of the Hex 

Wrench as shown.

5. Unless also installing a Front Mounted Antenna, 

insert the Hole Plug (Part #35959) into the open 

antenna hole in the Flange Bracket by aligning the 

flat sides of the plug with those of the bracket hole 

and pushing into place until flush.

6. Install the Front Tie Bracket (Part #25991) into 

the open slot in the right side of the M2T Chassis 

Cover Panel with the protruding nuts facing rear-

ward, affix with two (2) Cap Screws (Part #28885) 

provided and firmly tighten with the Hex Wrench. 

See next page.

NOTE: Steps 7-11 require parts from the 

(RMPM2T-1) M2T Single Rack Mount Kit.

Single Rack Mount Kit for M2T and DSQD