Sierra M6
‐
2 SAS/SATA Protocol Analyzer User Manual
167
Target and Device Emulation
LeCroy Corporation
Click the down arrow on the Primitive list box, choose a primitive, enter a value for the
number of primitives to send, and click
OK
.
Drop link for ... ms
Check and enter time value for which to drop the link.
Drop link after ... ms for ... ms
Check and enter time value for which to wait before dropping the link and time value for
which to drop the link.
Retain Error Injection Counters after Link Reset
If unchecked, after every Link Reset, the Emulator resets its internal Command Number/
Counters and re
‐
initializes the Error injection core. If checked, the Emulator keeps the
state.
Retain Error Injection Counters after drop link error injection
If unchecked, after every Link Reset, the Emulator resets its internal Command Number/
Counters and re
‐
initializes the Error injection core. If checked, the Emulator keeps the
state.
Buffer Starvation (SAS only)
Enter
Number
of
R_RND
in
each
connection
.
Send ... Hard Reset after PHY Reset (SAS only)
Specify number of resets to send.
Send FIS (SATA only)
Check
Send
stand
‐
alone
FIS
, select the FIS Type button, and optionally enter
User Defined FIS Data.