User manual of EL8-EC***F AC Servo
278
signal edge.
Please take note:
(
i
)
Triggering mode: Single trigger, rising signal edge = valid; triggering mode:
Continuous trigger, rising and falling edge = valid
(
ii
)
After activation, trigger signal selection, triggering signal edge settings, counter will be
reset and 0x60B9 status will change as well.
(
iii
)
Probe signal level is shown in 60FD: EXT1 -> bit 26, EXT2 -> bit 27.
Related Objects
Index
Sub
Index
Label
Access
Data
Type
Units
Range
Default
2007h
00h
Probe 1 polarity setting
RW
Uint16
0~0xFFFF
1
2007h
01h
Probe 2 polarity setting
RW
Uint16
0~0xFFFF
1
60B8h
00h
Probe control word
RW
Uint16
0~65535
0
60B9h
00h
Probe status word
RO
Uint16
0~65535
0
60BAh
00h
Probe 1or Z-signal rising
edge latching position
RO
int32
Command
unit
-2147483648
~2147483647
0
60BBh
00h
Probe 1 or Z-signal falling
edge latching position
RO
int32
Command
unit
-2147483648
~2147483647
0
60BCh
00h
Probe 2 or Z-signal rising
edge latching position
RO
int32
Command
unit
-2147483648
~2147483647
0
60BDh
00h
Probe 2 or Z-signal falling
edge latching position
RO
int32
Command
unit
-2147483648
~2147483647
0
60D5h
00h
Probe 1 or Z-signal rising
edge counter
RO
Uint32
0~429496729
6
0
60D6h
00h
Probe 1 or Z-signal falling
edge counter
RO
Uint32
0~429496729
6
0
60D7h
00h
Probe 2 or Z-signal rising
edge counter
RO
Uint32
0~429496729
6
0
60D8h
00h
Probe 2 or Z-signal falling
edge counter
RO
Uint32
0~429496729
6
0
6.17.2 Signal Input of EXT1 and EXT2
EXT1
:
Pin1 and Pin5 of CN1 terminal
EXT2
:
Pin2 and Pin6 of CN1 terminal
6.17.3 Probe Control Word 60B8h
Bit
Definition
Details
0
Probe 1 enable
0--Disable
1--Enable
1
Probe 1 mode
0--Single trigger mode
1--Continuous trigger mode