Leadshine CS-D808 User Manual Download Page 14

                                                                                  CS-D808 Closed Loop Stepper Drive User Manual                                                             

 

 

Page | 11   

 

13. Warranty

 

Twelve Month Warranty   

Leadshine Technology Co., Ltd. warrants its products against defects in materials and workmanship for a period of 12 

months from shipment

 

out of factory. During the warranty period, Leadshine will either, at its option, repair or replace 

products which proved to be defective. 

Exclusions                                                                                                                           

The  above  warranty  does  not  extend  to  any  product  damaged  by  reasons  of  improper  or  inadequate  handlings  by 

customer,  improper  or  inadequate  customer  wirings,  unauthorized  modification  or  misuse,  or  operation  beyond  the 

electrical specifications of the product and/or operation beyond environmental specifications for the product. 

Obtaining Warranty Service                                                                                     

To obtain warranty service, please contact your seller to obtain a returned material authorization number (RMA) before 

returning product for service. 

Shipping Failed Products         

                                                                                           

If your product fail during the warranty period, please contact your seller for how and where to ship the failed product 

for warranty or repair services first, you can also e-mail customer service at 

[email protected]

 to obtain a returned 

material authorization number (RMA) before returning product for service. Please include a written description of the 

problem along with contact name and address. 

 

Summary of Contents for CS-D808

Page 1: ...Loop Stepper Drive Revision 1 0 2016 Leadshine Technology Co Ltd Address Floor 11 Block A3 Nanshan iPark Xueyuan Avenue 1001 Shenzhen Guangdong 518055 China Tel 86 755 26409254 Fax 86 755 26402718 We...

Page 2: ...therwise without approval from Leadshine While every precaution has been taken in the preparation of the book Leadshine assumes no responsibility for errors or omissions Neither is any liability assum...

Page 3: ...4 3 3 Connector P4 Motor and Power Supply Connection 5 3 4 Connector P5 RS232 Connection 5 3 5 LED Light Indication 5 4 Motor Selection 5 5 Power Supply Selection 5 5 1 Regulated or Unregulated Power...

Page 4: ...reduced heating lower noise low vibration 1 1 Features No loss of step No torque reservation No hunting or overshooting No tuning for easy setup Low noise and vibration smooth motion 30 80VDC supply v...

Page 5: ...ation 10 50Hz 0 15mm Storage Temperature 20 C 65 C 4 F 149 F Weight Approx 570 g 20 2 Oz 2 3 Mechanical Specifications unit mm 1inch 25 4mm Figure 1 Mechanical specifications 2 4 Heat Dissipation CS D...

Page 6: ...gnals 4 Pulse width should be set to 2 5 s or longer PUL I DIR I Direction signal 1 In single pulse step direction control mode this signal s low and high voltage levels represent the two directions o...

Page 7: ...ts open collector and PNP output A CS D808 has 3 optically isolated control inputs PUL DIR and ENA Refer to the following two figures for connections of open collector and PNP signals Controller Contr...

Page 8: ...tuning purpose only not for RS232 command controls 3 5 LED Light Indication There are two LED lights for CS D808 one red and one green The GREEN one is the power indicator which will be always on gen...

Page 9: ...e drive draws current from the power supply capacitor of the unregulated supply only during the ON duration of the PWM cycle but not during the OFF duration Therefore the average current withdrawn fro...

Page 10: ...12800 off on off on 25600 on off off on 51200 off off off on 1000 on on on off 2000 off on on off 4000 on off on off 5000 off off on off 8000 on on off off 10000 off on off off 20000 on off off off 40...

Page 11: ...ension Cable Power Cable 3 B B Yellow Green Blue CS D808 Fault 5V ALM 1 2 ALM In Positiion Pend 1 2 Pend Figure 6 Typical connection 8 Sequence Chart of Control Signals In order to avoid some fault op...

Page 12: ...u want to do fine tuning or custom configurations such as micro step current percentage change you can use Leadshine s free ProTuner software to make the changes Download ProTuner at http www leadshin...

Page 13: ...el is reverse Toggling the SW5 DIP switch The drive in fault Red light flashes once in a 5 second period The motor coil may short circuit or exiting the wrong wiring Red light flashes twice in a 5 sec...

Page 14: ...ation or misuse or operation beyond the electrical specifications of the product and or operation beyond environmental specifications for the product Obtaining Warranty Service To obtain warranty serv...

Page 15: ...h 24VDC brake CS M23480 8 0 1132 127 3 03 0 551 inch 14 mm shaft CS M23480 S 8 0 1132 127 3 82 0 50 inch 12 7 mm shaft CS M23480B 8 0 1132 173 3 82 0 551 inch 14 mm shaft with 24VDC brake CS M23485 8...

Page 16: ...or stepper and servo controls Model Output Voltage VDC Series Model Continuous Current A Max Current A Input Voltage VAC RPS488V20 48 RPS 8 3 24 9 85 132 176 264 RPS4810V20 48 10 5 31 5 85 132 176 264...

Reviews: