165
16. EXTERNAL INTERFACE
16. EXTERNAL INTERFACE
16.1 Remote Control Feature
You can use the remote connector on the rear panel to load presets, transmit alarm signals,
and perform other operations. Use the supplied 15-pin D-sub connector to control the LV 5333.
● Pinout
This section contains a diagram of the remote control connector, displayed as it appears on
the rear panel, and a table that describes the connector's pinout.
Figure 16-1 Remote control connector (female, inch screws)
Table 16-1 Remote control connector pinout
Pin No.
Name
I/O
Function
1
GND
-
Ground
2
/P1
I
Recall preset 1
3
/P2
I
Recall preset 2
4
/P3
I
Recall preset 3
5
/P4
I
Recall preset 4
6
/P5
I
Recall preset 5
7
/P6
I
Recall preset 6
8
/P7
I
Recall preset 7
9
/P8
I
Recall preset 8
10
/ACH
I
Select channel A
11
/BCH
I
Select channel B
12
RESERVED
I
Reserved
13
TALLY
I
Tally display
14
ALARM
O
Alarm output
15
GND
-
Ground