13. STATUS DISPLAY
STATUS → F•5 ERROR CONFIG → F•2 COUNT RATE: V RATE / 1sec
F•5
13.6.2
Selecting the Error Count Rate
If an error occurs in an item whose detection has been enabled with
an error count is displayed next to ERROR COUNT on the status screen.
ERROR DETECT,
To select the error count rate displayed next to ERROR COUNT, follow the procedure below.
Procedure
Settings
V RATE:
An error is counted for each field (when the input signal is interlace or
segmented frame) or each frame (when the input signal is progressive). Even if
multiple errors occur within the same field (frame), the error count increases by
1.
1sec:
Errors are counted for each second. Even if multiple errors occur within a
second, the error count increases by 1.
13.6.3
Configuring Error Detection Settings
To configure the error detection settings, press
ERROR DETECT on the STATUS menu.
→
ERROR CONFIG →
ERROR DETECT →
Figure 13-20 ERROR DETECT menu
INTERN
AL
INT&TR
AP
INT&RM
T
ALL ON
OFF
Error display in the upper right of the screen
Yes
Yes
Yes
Yes
No
Error display on the status display
Yes
Yes
Yes
Yes
No
Error display in the event log
Yes
Yes
Yes
Yes
No
SNMP trap output
No
Yes
No
Yes
No
Alarm output from the remote connector
No
No
Yes
Yes
No
● Detecting TRS Errors
To detect TRS errors, follow the procedure below.
F•3
F•3
F•3
STATUS