User Manual
Technical Specifications
Page 3 of 22
Any modifications to the device or its components are prohibited and do
not conform to its intended use.
Observe the following safety instructions:
Device defect due to incorrect installation: Install the device in a dry
and cool location.
Danger from damaged, frozen or deformed batteries:
Before operation, make sure that the battery is undamaged and the
electrolyte is not frozen.
Only charge batteries in well-ventilated rooms and away from ignition
sources.
When handling open batteries, wear acid-proof clothing.
3
Technical Specifications
12-V Devices
Model
1012-50
1312-80
1512-80
2012-100
Output power
Continuous power
1,000 W
1,300 W
1,500 W
2,000 W
Overload (1 s)
2,000 W
3,000 W
3,000 W
4,000 W
Overload (10 s)
1,500 W
1,800 W
2,000 W
2,800 W
Overload (15 min)
1,200 W
1,500 W
1,700 W
2,200 W
Degree of efficiency
>90%
Internal consumption
Normal idling speed
10 W
15 W
Idling with search mode
< 2 W
Standby mode
< 5 mA
Operating temperature
Max. operating
temperature
+50°C
Min. operating
temperature
-20°C
Switch-off temperature
+80°C
Output voltage (AC)
Nominal voltage
230 V
Voltage tolerance
-10% ... +5%
Frequency
50 Hz
Voltage waveform
Sine
Max. distortion (THD)
3%