LEAB BW 801e Quick Start Manual Download Page 1

Battery Watch

BW 801e

Quick start guide
V 2

General Safety

This guide supports safe handling of the product. Use the product
only in accordance with its intended use:

The BW 801e battery monitor is a two-stage safety system for pre-
venting deep discharge for batteries with a nominal voltage of 12 V
or 24 V.

Audible and visual alarms warn you of an approaching deep dis-
charge. If power continues to be removed from the battery, the bat-
tery monitor disconnects consumers from the battery to prevent
deep discharge. The threshold values for the alarm and for switch-
ing off the consumers are set via DIP switches.

Any modifications to the product or its components are prohibited
and do not conform to its intended use. Only use original LEAB or
LEAB-approved accessories.

Observe the safety instructions:

 WARNING! 

Incorrect assembly or inadequate wiring can cause

a fire: Only install the unit as described in these instructions and se-
lect a sufficient cable cross-section for connecting the device.

 WARNING! 

Risk of injury from electric shock: Disconnect the

battery negative lead prior to assembly/disassembly.

NOTE! 

Incorrect usage can damage the device: Only use the

device within the specified operating parameters.

NOTE! 

Install the device in a dry and cool location.

NOTE! 

Residual voltage can cause damage: Do not place the pos-

itive lead on the vehicle bodywork.

Package Contents

No.

Name

1x

BW 801e battery monitor

2x

Insulating cap (400N9V02)

1x

3-colour LED

Accessories

Part number Name

1401036701

3-colour LED in socket with cable (5m)

1401036702

3-colour LED in socket with cable (1m)

Technical Specifications

Part no.: 1305041043

Modell

BW 801e

Nominal voltage (DC)

12 V or 24 V

Continuous load

50 A

Overload (10 s)

70 A

Switch-off voltage

12 V: 9 V … 12 V;
24 V: 18 V … 24 V (adjustable)

Operating temperature

-30 °C … +70 °C

Internal consumption

6 mA

Dimensions (L x W x H)

100 mm x 90 mm x 25 mm

Weight

0.11 kg

Setting the Threshold Values (DIP Switches)

DIP ON

Switch-off

voltage [V]

Alarm

threshold [V]

Switch-on

voltage [V]

1

2

3

4

12 V

24 V

12 V

24 V

12 V

24 V

0

0

0

-

9

18

9.5

19

10.5

21

1

0

0

-

9.5

19

10

20

11

22

0

1

0

-

10

20

10.5

21

11.5

23

1

1

0

-

10.5

21

11

22

12

24

0

0

1

-

11

22

11.5

23

12.5

25

1

0

1

-

11.5

23

12

24

13

26

0

1

1

-

12

24

12.5

25

13.5

27

1

1

1

-

-

-

-

-

-

-

-

-

-

0

Internal buzzer on

-

-

-

1

Internal buzzer off

LEAB Automotive GmbH

Thorshammer 6
DE-24866 Busdorf
Tel: +49 (0) 4621 9 78 60-0
Fax: +49 (0) 4621 9 78 60-260
[email protected]

It is prohibited to copy, duplicate, translate or otherwise
pass on the content of this guide to third parties without the
express written permission of LEAB.

We make energy mobile.

Reviews: