Installation instructions
About the battery
Page 7 of 18
Detail view of status indicator and signal contacts
Status indicator (left)
Signal contacts (right)
LED
Indicator
Status
Power (blue)
Steady light
Device on
Flashing
Charging
Failure (red)
See page 17
100% (green)
Steady light
> 90 %
Flashing
80 % … 90 %
80 % (green)
Steady light
> 70 %
Flashing
60 % … 70 %
60 % (green)
Steady light
> 50 %
Flashing
40 % … 50 %
40 % (green)
Steady light
> 30 %
Flashing
20 % … 30 %
20 % (red)
Steady light
> 10 %
Flashing
0 % … 10 %
Signal contact
Description
Output 1
External alarm controller (active at <10% SOC)
Output 2
Protection against overload by an external charger
(active at > 4.1 V cell voltage)
Input 1
Wake-up signal for vehicle ignition
(active operating voltage, D+ signal)
Input 2
Wake-up signal for remote control signal
(active operating voltage)
Input 3
Wake-up signal for 230 V network (active at low range)
ground. Do not apply 230 V AC voltage.
SW data
Communication port for external device
SW GND
Communication port to ground
GND
Ground connection