5.2.
Control Panel
The Salamander Quad Pro is configured through an on board control panel featuring a 3 x 7-Segment
LED display, 5 x indicator LEDs and 4 x multi-function buttons.
Figure 2: Salamander Quad Pro Control Panel
5.3.
DMX Operation
The Salamander Quad Pro can only be operated through DMX-512. Five channels are required – one
channel activates the HSI, the remaining four channels each operate one firing solenoid.
Two independent addresses can be set. The first address is for the HSI channel, the second address is
the first of four fire channels. The three remaining fire channels will be the three consecutive
channels.
For Example:
HSI – Channel 12. FLAME – Channel 2. HSI will be activated by channel 12. The fire channels will be 2,
3, 4 and 5.
The order of the canister channels can be seen in Figure 3.
5.4.
Shutdown
Each of the following steps disables the machine. The order presented is for a recommended
normal shutdown procedure. In case of an emergency always perform the easiest, safest and
quickest step available first.
1.
Disarm via the control system – set HSI DMX channel (and all fire channels) value to 0.
2.
Cut the power to the machine.