1) PV Power

This interface show the solar panels current output power.

2) Accumulated Charging Power(AH): Accumulate the charging power of this system. Long

press“→”button to reset.

3) Accumulated Discharging Power(AH): Accumulate the discharging power of this system.

Long press“→”button could reset.

4) Float Voltage: When the battery voltage reach this set point, the controller will start constant

voltage charging mode, limit the rising of battery voltage, decrease the charging current, and

keep the battery in full condition. Press “←”button enter into menu interface of float voltage.

Long press “←”button≥5S, the parameter in the main interface will flash, and here is setting

up state. Loose the button, and short press “←”or“→”could modify the data. After set the

needed data, long press“←”≥5S to save the data and exit. If no operation in 20s, it will

automatically back to the main interface.

5) Boost Voltage: When the battery voltage is less than 12.6V, the constant voltage will auto

reach up to 14.4V and back to float voltage after 2 hours’ charging.

6) Low Voltage Reconnect Voltage(LVR): After the controller detect the low voltage of load and

stop the output, battery voltage must be higher than LVR voltage if it reconnect the output.

Or press “→” in the main interface to release. The procedure is the same as (4).

7) Low Voltage Disconnection Voltage(LVD): When the controller detect the battery voltage is

less than LVD point, the output will be immediately shut down. At the same time, the status

of controller is in lock. Users have to charge the battery, and the load will reconnect when

the battery voltage is higher than LVD voltage or press “→” in the main interface to release.

The procedure is the same as (4)

8) Load Working Mode Selection: The system default load working time is 24h. When the Load

Working Time is set to 24hours, the load will keep working 24hours if there is no fault. When

the load working time is set to ≤23H, it means starting the load timer or sensor function. The

procedure is the same as (4). If the battery capacity is enough, the load will start-up at

sunset and work in set hours or stop working till sunrise.

When the load come into timer or sensor mode, if the set working time is more

than actual night time, the load output will be closed at sunrise, although the

working time is not reach the set hours. For example, the local actual night

time is 10hours, and the working time user set at night is 12hours. But when

the sunrise 10hours later, the output will be closed automatically.

No matter how many hours after the sunrise will be zeroing and the load will

work with next sunset.

9)

Controller inside Temperature detection:

When the inside temperature of controller is

more than 75

, the charging current will be reduced. It will stop charging when the

temperature exceed 85

.

10) Battery Type Selection: 3 types battery data

in the internal system

. Different battery refer to

different parameter. (Default SEL battery parameter)

Attention: About the control parameter of battery, we have taken every working condition

into consideration. Hence, if customers want to adjust the parameter, please refer to

battery suppliers’ suggestion, or unreasonable adjust will destroy battery.

Protection Function

Fault Symbol Indication

State

Symbol

Condition

LVD Protection

Empty Battery and Warning Flash

together

Battery Over

Voltage

Protection

Full Battery and Warning Flash

together

Load Over

Current

Protection

Load and Warning Flash together

Controller Over

Temperature

Protection

Temperature symbol and

Warning Flash together

Solar Panel Over

Voltage

Protection

Solar Panel symbol and Warning

Flash together

Solar Panel Short Circuit and Reverse Connected Protection

When the solar panels have input short circuit or reverse connection, the controller will be

stopped charging immediately until correcting the faults.

Solar Panel Over Voltage Protection

When solar panel input voltage is more than 100V, the controller will be stopped charging

immediately until the input voltage is less than 100V.

Battery Reverse Connection Protection

If the battery reverse connect, the controller won’t be damaged and will normally work after

corrected the connection.

Battery Over Voltage Protection

When the voltage of battery is more than 16.5V, the controller will be automatically stopped

charging and discharging to avoid the damage of the battery and loads.

Summary of Contents for Tracer Dream TD2210

Page 1: ...ypes of battery Sealed Gel and Flooded alternative charging procedure Temperature Compensation Function Function of accumulated charging and discharging power as well as real time display power generation Fullest digital protection functions Reverse connection Overcharging Over discharging Over voltage Overload Short circuit Unique 16mm2 connectors red and black connectors distinguish positive and...

Page 2: ...roller could detect the environmental temperature to adjust the charging voltage Accordingly the controller should be closed to battery as near as possible 2 Recommend system current density of cables should be less than 3A mm2 Unreasonable selection of cables will increase the system consumption or even causing burning 3 Try to use multi strand copper wire in order to connect with the terminal mo...

Page 3: ...ly and do not connect them with controller otherwise the terminals of load may not be started or even be destroyed 4 Insert external temperature sensor external temperature sensor is used for temperature compensation Please let it close to the battery as near as possible If the temperature sensor doesn t be plugged in the controller will default 25 5 RS485 communication interface Monitor the contr...

Page 4: ...er Main Interface If no operation in the main interface in 10s the main interface will rotate the battery voltage environmental temperature and battery type at 3s intervals Long press could speed loop display Short press in the main interface could on or off the load Long press and together 5s in the main interface could show operation log such as number of LVD working days number of over current ...

Page 5: ...t hours or stop working till sunrise When the load come into timer or sensor mode if the set working time is more than actual night time the load output will be closed at sunrise although the working time is not reach the set hours For example the local actual night time is 10hours and the working time user set at night is 12hours But when the sunrise 10hours later the output will be closed automa...

Page 6: ...correctly and firmly The controller is displaying LVD The battery is over discharging Please check if the system design is reasonable Please full charge the battery The controller is displaying Over Voltage Protection of battery The voltage of battery is too high Please first cut off the solar panel and see if the voltage get down to normal level If not please disconnect the battery with controlle...

Reviews: