background image

01154020

01154120
01154030
01154130

Arpa

 

8/22

 

150

 

W

 

LED,

 

3200K

Arpa

 

8/22

 

150

 

C

 

LED,

 

5600K

Arpa

 

18/36

 

W

 

LED,

 

3200K

Arpa

 

18/36

 

C

 

LED,

 

5600K

istruzioni

 

per

 

l'uso

operating

 

instructions

Bedienungsanleitung

instrucciones

 

de

 

manejo

mode

 

d'emploi

gebruiksaanwijzing

Luci

 

della

 

Ribalta

 

srl,

 

Via

 

Berna

 

14,

 

46042

 

Castel

 

Goffredo

 

mn

 

Italy.

 

tel

 

+39

 

0376

 

771

 

777

 ‐ 

fax

 

+39

 

0376

 

772

 

140

 ‐ 

email

 

[email protected]

Summary of Contents for Arpa 01154020

Page 1: ...rpa 18 36 W LED 3200K Arpa 18 36 C LED 5600K istruzioni per l uso operating instructions Bedienungsanleitung instrucciones de manejo mode d emploi gebruiksaanwijzing Luci della Ribalta srl Via Berna 14 46042 Castel Goffredo mn Italy tel 39 0376 771 777 fax 39 0376 772 140 email info ldr it ...

Page 2: ...ess 5 9 3 Dimmer resolution 5 9 4 DMX frequency control 5 9 5 Lost DMX signal 6 9 6 Strobe 6 9 7 Strobe speed 6 9 8 Dimming curve 6 9 9 Cut off dimming response 7 9 10 Dimming behaviour 7 9 11 LED frequency adjustment 7 9 12 LCD retro illumination 7 9 13 Software version and LED temperature 7 9 14 PRO BASIC 8 9 15 Reset 8 MAINTENANCE 6 Fuse replacement 8 7 Cleaning and maintenance 8 8 Spare parts ...

Page 3: ...ntioned in this manual as well as those generally applicable to this lighting equipment may cause the luminaire not to perform as expected Luci della Ribalta accepts no liability for direct indirect incidental special or consequential damages resulting from the customer s failure to follow the installation operating maintenance and safety procedures in this manual or those generally applicable to ...

Page 4: ... a LED solid state electronic light source which is more energy efficient and longer lasting than a tungsten halogen lamp The implications of using a LED source are as follows A 128W LED is built in to the spotlight and when the time comes to replace it this will require servicing via your local dealer The LED is not a plug in replacement component and is not user serviceable The colour temperatur...

Page 5: ... the connection points on your plug please proceed as follows The green or green and yellow wire must be connected to the connection point marked with the letter E or with the symbol or coloured in green or in green yellow The blue wire must be connected to the connection point marked with the letter N or coloured in black The brown wire must be connected to the connection point marked with the le...

Page 6: ... initial DMX address press the rotary switch until an arrow appears then turn to change to the desired DMX starting address Press to confirm your selection Factory setting is 001 9 3 DIMMER RESOLUTION 8 16b The dimming resolution can be controlled at 8 bits from one DMX channel to 16 bits with 2 DMX channels Factory setting 8 Bit 9 4 DMX FREQUENCY CONTROL DMXCfg If turned ON it allows to remotely ...

Page 7: ...curve for the Cetra LED A choice of three curves is available LED HAL to reproduce halogen behavior square and linear Factory setting LED HAL PRESS TO ACTIVATE THE MENU AN ARROW SHOULD APPEAR 5 DMXMem ON LAST SCENE HOLD 1 Mode ON 5 DMXMem OFF 80 DIM THE LED TO 80 OF ITS MAXIMUM POWER 5 DMXMem OFF 0 DIM THE LED TO 0 6 Strobe DISABLE 6 Strobe DISABLE 6 Strobe ENABLE TURN TO SELECT MANUAL OR DMX AND ...

Page 8: ...ecomes inactive Factory setting 2kHz 9 12 LCD SCREEN ILLUMINATION BackL This function allows to turn off the LCD backlight after 1 30 from last setting Factory setting AutoOFF 9 13 SOFTWARE VERSION AND TEMPERATURE CONTROL V 1 0 This function allows to visualize the software version and the LED temperature in C 9 14 PRO or BASIC CONTROL ProBasic PRESS TO ACTIVATE THE MENU AN ARROW SHOULD APPEAR 9 C...

Page 9: ...pe 6 3A 5x20mm 250 VAC DC fast blow fuse CAUTION Replace the fuse only when power is disconnected 11 CLEANING AND MAINTENANCE To ensure maximum performance of the product a regular maintenance service should be carried out Please make sure the product is cold and disconnected from power supply when doing this clean all lenses opening the product if necessary check the COB and the lenses and replac...

Page 10: ...motely controlled through DMX DMXCfg function enable OPEN ON SPEED xx select value from 01 slowest to 10 fastest CLOSED OFF OPEN 8 Curves select the dimming curve LED HAL SQUARE LINEAR LED HAL 9 CutOff replicate the halogen lamp dimming behaviour at cut off FAST NOT ACTIVE SLOW ACTIVE SLOW 10 Smooth dimmere response OFF Immediate response SLOW 300ms FAST 150ms Smooth 11 Freq set the LED frequency ...

Page 11: ...14 FOLLOWING THE PROVISIONS OF EU LOW VOLTAGE DIRECTIVE LVD 2014 35 EU LIMITS AND METHODS OF MEASUREMENTS OF RADIO DISTURBANCE CHARACTERISTICS OF ELECTRICAL LIGHTING AND SIMILAR EQUIPMENT EQUIPMENT FOR GENERAL LIGHTING PURPOSES EMC IMMUNITY REQUIREMENTS ELECTROMAGNETIC COMPATIBILITY EMC PARTS 3 2 LIMITS LIMITS FOR HARMONIC CURRENT EMISSIONS EQUIPMENT INPUT CURRENT UP TO AND INCLUDING 16 A PER PHAS...

Page 12: ...toso Faulty product Defekte s Produkt Produit défectueux Producto defectuoso Descrizione del problema Problem found Beschreibung des Defekts Description du défaut Descripciòn del problema ________________________________________________________________________________________________________ ________________________________________________________________________________________________________ __...

Page 13: ...ble for delivering the appliance to an appropriate collection facility at the end of its useful lifespan Appropriate separate collection to permit recycling treatment and environmentally compatible disposal helps prevent negative impact on the environment and human health and promotes recycling of the materials making up the product For more information on available collection facilities contact y...

Page 14: ...Luci della Ribalta srl Via Berna 14 46042 Castel Goffredo mn Italy tel 39 0376 771 777 fax 39 0376 772 140 email info ldr it ...