INSTALLATION INSTRUCTIONS
Read instructions carefully before attempting to install fixture. Save these instructions.
WARNING:
Disconnect power during installation and before servicing.
SAFETY:
This fixture must be wired in accordance with the National Electric
Code,
and
applicable local codes and ordinances.
Proper grounding is required to insure personal safety.
A qualified electrician should perform all wiring.
Junction Box install method
Remove the Junction Box side cover screw.(Remove only one screw of the Junction Box), depends which way
the wire comes into the junction Box, install the UL listed conduit(1/2 trade size) and UL listed conduit
fitting(waterproof) to the junction Box, also the Junction Box just for one light fixture
Ceiling Mounting:
“version A”
1. Attach the cast junction box to surface with screws (hardware by others).
2. Run conduit to junction box if application calls for it
and pull supply leads into junction box with at least 6” lead showing.
Note: Be sure to use Teflon tape to seal 1/2" NPT threads for Wet Location Environments!
3. Place gasket (from polybag) and make wiring connections from driver in LED Heatsink to supply leads as indicated
below on
“Wiring Connections”
.
4. Remove PC Lens
with the gasket in place, attach LED Heatsink to junction box by using the two (2)
screws provided
in polybag. Insert the screws through the holes on the inside of LED Heatsink. Next align the screws with
the holes on
the “Adaptor Plate” mounted on the “Junction Box”and
tighten.
5. Replace PC Lens
onto fixture by threading until tight (care must be given to not cross thread).
Wall Mounting:
“version B”
1.
Attach the cast junction box to surface with screws (hardware by others).
2. Run conduit to junction box if application calls for it
and pull supply leads into junction box with at least 6” lead showing.
Note: Be sure to use Teflon tape to seal 1/2" NPT threads for Wet Location Environments!
3.
Connect the wires from the“Quick Disconnect”wiring harness provided i
n polybag, to the supply side wires from the
junction box as
indicated below on “Wiring Connections”.
4. Next m
ount the “Wall Bracket”, first p
lace gasket between J
- box and Wall
Bracket then insert the “Quick Disconnect
wiring harness through the inside of Wall Bracket, now attach Wall Bracket to junction box using the four
(4) 3/4” long
screws provided in polybag and tighten securely.
5. Next, using gasket provided in polybag, thread wiring through the gasket opening. Take the LED Heatsink and snap
together the
two (2) “Quick Disconnects” one leading from the driver and the other
coming out from the Wall Bracket.
6. Remove PC Lens
attach LED Heatsink to Wall Bracket using the two (2) screws provided in polybag.
Insert the screws through the holes on the inside of LED Heatsink. Next align the screws with the holes on the Wall
Bracket and tighten securely.
7. Replace PC Lens
onto fixture by threading until tight (care must be given to not cross thread).
LEVP-14W LED Series
Form #D-1281 LDPI, Inc. 1-800-854-0021 Web:http://www.ldpi-inc.com Email: [email protected]
(Glass & Guard),
(Glass & Guard),
(Glass & Guard),
(Glass & Guard),
Page1