MICROPHONE STATION STATUS DISPLAY
To view the status information of individual microphone stations, adjust the individual volume and in order to make changes in the micro-
phone station menu, press the switch corresponding to the desired microphone station (in this example RX1 = MIC 1). To adjust the volume,
use the pressure rotary encoder PUSH TO ENTER (rotate right = increase volume, rotate left = lower volume). In order to make changes in
the microphone station menu, press on the pressure rotary encoder.
Switch RX 1 - RX 4
Battery status
Frequency channel and frequency group
- Active antenna and radio signal level
- Audio signal level with Peak display (PK)
- Volume adjustment
Microphone station with priority
Mute function activated (mute)
Microphone station number and radio frequency
IR SYNC RUN
To synchronise the microphone station with the radio channel set in the receiver, bring the infrared port of the microphone station in direct visual
contact with the infrared port of the receiver (distance approx. 10 cm) and turn on the microphone station. Press the switch corresponding to
the desired microphone station (in this example RX 1 = MIC 1) and then press the pressure rotary encoder
PUSH TO ENTER. Now select the IR SYNC RUN menu item by rotating the encoder (light background) and press the encoder once more to
launch the synchronisation process. After a few seconds, the process is completed and the display of the microphone station switches for a
short time to “IR SYNC
”, confirming successful synchronisation. When daisy-chaining the receivers, the microphone station numbers are
assigned automatically (Master = MIC 1 - 4, Slave 1 = MIC 5 - 8, Slave 2 = MIC 9 - 12, Slave 3 = MIC 13 - 16, Slave 4 = MIC 17 - 20). The
microphone station numbers are automatically transmitted to the microphone station during the synchronisation process and are shown on the
display. To cancel the operation, press the encoder. To return to the main display, select EXIT now by rotating the encoder (light background)
and confirm by pressing the encoder. Then press the switch corresponding to the desired microphone station (RX 1 - 4). After approximately 10
seconds of inactivity, the display will automatically return to the main screen.
FREQ AUTO RUN
Automatic frequency search (frequency scan) to determine an interference-free radio frequency in the current environment and to allow for
optimal reception. For this purpose, leave the corresponding transmitter off, but other radio systems turned on, if necessary. To start the
automatic frequency search, press the switch corresponding to the desired microphone station (in this example RX 1 = MIC 1) and press
the pressure rotary encoder PUSH TO ENTER. Now select the FREQ AUTO RUN menu item by rotating the encoder (light background). To
confirm the operation, press the encoder. Progress is now indicated on the display by an animation and the scanning process is completed
after a few seconds (to cancel, press the encoder). The resulting frequency is automatically enabled and, as in “IR SYNC RUN”, you can now
switch on the transmitter and synchronise it with the receiver. To return to the main display, select EXIT now by rotating the encoder (light
background) and confirm by pressing the encoder. Then press the switch corresponding to the desired microphone station (RX 1 - 4). After
approximately 10 seconds of inactivity, the display will automatically return to the main screen.
CHANNEL
Menu item to manually adjust the frequency channel. Press the switch corresponding to the desired microphone station (in this example RX
1 = MIC 1) and then press the pressure rotary encoder
PUSH TO ENTER. Now select the CHANNEL menu item by rotating the encoder (light background) and press the encoder 2x to adjust the
frequency channel as desired by rotating the encoder. Confirm the entry by pressing the encoder. If you press the encoder only 1x, you can