LCN 8310-2300 Series Installation Instructions Download Page 1

Models 8310-2310, -2320, -2330, -2340

Installation Instructions

Description

Available faceplates:

 

L

Note: A minimum depth of 2-3/4” for all box installations, and mortised holes 

when not using a box, is recommended.

8310-2310 (Single Gang): 2-3/4” x 4-1/2” stainless steel, fits on single gang electrical 

boxes.
8310-2320 (Double Gang): 4-1/2” x 4-1/2” stainless steel, fits on single gang or double 

gang boxes (required adapter plate included).
8310-2330 (Jamb Style): 1-3/4” x 4-1/2” stainless steel, has a custom mounting 

without a box. See the installation section below.
8310-2340 (Round): 6” Diameter, fits on single or double gang boxes (required adapter 

plate included).

Technical specifications

Descriptions

8310-2300 Series

Number of IR sensors

1

Batteries (supplied)

“AA” alkaline batteries

Estimated battery life

2 years (based on 100 operations/day)

Standard operating range

1” - 12” (25.4mm - 304mm) 

Factory set to 6” (152mm)

Operating mode

Momentary 

Momentary with alarm

Inputs

“Request to Exit” external (door contact) input

Wireless output

Hard-wired transmitter

Relay output

1 form “C” (SPDT)

Relay contact rating

2 Amps @ 30 VDC

Output type

Normally Open or Normally Closed

Installation

Mounting

The touchless actuator may be mounted in conventional 2-3/4” deep metal or plastic electrical gang boxes. Ensure that 

the unit sensor does not come in contact with the metal gang box to avoid shorting out the unit.
Do not place the sensor in the door’s opening range, where the sensor may see door movement. Do not place moving 

objects in front of the sensor.
Use the weather resistant gasket as a protective barrier against the elements.
For electrical box installation, refer to the instructions that come with the product.

 

L

NOTES: Plastic mounting boxes are required for use when using transmitters. 

 

A minimum depth of 2-3/4” for all box installations, and mortised holes when not using a box, is recommended. 

 

Actuators are recommended for interior use only!

Single gang electrical box (Single gang, double gang and round faceplates):

1.  If using an in-wall box ensure the box is plumb and square, and flush with the wall surface. If using a surface box, ensure 

it is secure & plumb.

2.  Bring your 2-conductor wire through the back or side of the enclosure and leave approximately 6” tail for wiring 

connection. 

8310-2300 Series Touchless Actuator 

Battery powered contactless switch

WAVE

TO OPEN

TO OPEN

WAVE

WAVE

TO OPEN

WAVE

TO OPEN