Models 8310-2310, -2320, -2330, -2340
Installation Instructions
Description
Available faceplates:
L
Note: A minimum depth of 2-3/4” for all box installations, and mortised holes
when not using a box, is recommended.
8310-2310 (Single Gang): 2-3/4” x 4-1/2” stainless steel, fits on single gang electrical
boxes.
8310-2320 (Double Gang): 4-1/2” x 4-1/2” stainless steel, fits on single gang or double
gang boxes (required adapter plate included).
8310-2330 (Jamb Style): 1-3/4” x 4-1/2” stainless steel, has a custom mounting
without a box. See the installation section below.
8310-2340 (Round): 6” Diameter, fits on single or double gang boxes (required adapter
plate included).
Technical specifications
Descriptions
8310-2300 Series
Number of IR sensors
1
Batteries (supplied)
“AA” alkaline batteries
Estimated battery life
2 years (based on 100 operations/day)
Standard operating range
1” - 12” (25.4mm - 304mm)
Factory set to 6” (152mm)
Operating mode
Momentary
Momentary with alarm
Inputs
“Request to Exit” external (door contact) input
Wireless output
Hard-wired transmitter
Relay output
1 form “C” (SPDT)
Relay contact rating
2 Amps @ 30 VDC
Output type
Normally Open or Normally Closed
Installation
1
Mounting
The touchless actuator may be mounted in conventional 2-3/4” deep metal or plastic electrical gang boxes. Ensure that
the unit sensor does not come in contact with the metal gang box to avoid shorting out the unit.
Do not place the sensor in the door’s opening range, where the sensor may see door movement. Do not place moving
objects in front of the sensor.
Use the weather resistant gasket as a protective barrier against the elements.
For electrical box installation, refer to the instructions that come with the product.
L
NOTES: Plastic mounting boxes are required for use when using transmitters.
A minimum depth of 2-3/4” for all box installations, and mortised holes when not using a box, is recommended.
Actuators are recommended for interior use only!
Single gang electrical box (Single gang, double gang and round faceplates):
1. If using an in-wall box ensure the box is plumb and square, and flush with the wall surface. If using a surface box, ensure
it is secure & plumb.
2. Bring your 2-conductor wire through the back or side of the enclosure and leave approximately 6” tail for wiring
connection.
8310-2300 Series Touchless Actuator
Battery powered contactless switch
WAVE
TO OPEN
TO OPEN
WAVE
WAVE
TO OPEN
WAVE
TO OPEN