18.8 Breakdown of the front unhinging bracket with tool-free dismantling
The unhinging bracket is broken down using the following procedure:
➢
Dismantling:
A-
Remove the protective ABS cover
B-
Using an Allen key, loosen the set screw so that you can remove the nylon sleeve
C- Remove the unhinging detection sheet
D- Insert a clamp between the two buffers and the plastic support
E-
Compress the clamp so that the cylinder can be compressed to remove the two screws
holding the buffers on the unhinging plate
F-
Remove the two screws in order to release the guide sheet
G- Remove the buffers
H- Remove the cylinder