8. Audio IO
8.4
Setting Up Synchronisation
8.4.1
Sync Reference Parameters
"System -> Definition -> Parameter = Sync"
Open this branch of the 'Tree Definition' to configure the system's sync reference parameters. See
for more about the sync reference options and how to use the Web UI to check the sync
status.
The configuration parameters are defined as follows:
Parameter
Sync – reference name for the element.
Enable Sync from
PTP, MADI, etc.
When no boxes are ticked, the system is synchronised to internal system clock (either 48kHz
or 44.1kHz, see
Enable Samplerate Switch
below.)
To sync to an external reference, select the relevant tick boxes.
Sync Prio
If more than one sync source is enabled, then this menu sets the prioritization order.
Enable Samplerate
Switch
Select this tick box to enable the 44.1kHz sample rate switch (described below).
Samplerate 44.1kHz
Selects a logic control signal to switch the system sample rate from 48kHz (default) to
44.1kHz. To switch the sample rate you must check the
Enable Samplerate Switch
box AND
apply a logic control signal.