mc²56 MKII Technical Manual
V5.10.2/1
73
Chapter 2: Installation
System Connections
Nova73 to DALLIS Interconnects
The
of master board determines how each DALLIS unit connects to the Nova73. There are two possible
options: MADI or RAVENNA.
MADI
·
AES10, multi-channel digital audio interface.
·
Connections are either multi-mode or single-mode fibre, depending on the master board type; duplex-SC
connectors:
o
Multi-mode fibre: 62.5 / 125 µ m, 1300nm
o
Single-mode fibre: 9 / 125 µ m, 1300nm
·
Up to 64-channels at 48kHz, or 32-channels at 96kHz, per port.
A minimum of 4-channels are used to transport
to/from the DALLIS. This leaves up to
60-channels at 48kHz, or 28-channels at 96kHz, for plug-in I/O.
RAVENNA