mc²56 MKII Technical Manual
V5.10.2/1
281
Chapter 4: Service/Maintenance
Control Surface
Bay Server Rotary Switch Settings
Each channel and central bay is supported by an Ethernet
, mounted behind its TFT display. The Bay
Server has a rotary switch with two settings:
·
Function
- determines whether the Bay Server supports a channel or central GUI bay.
·
Address
– determines the Bay Server index, counted from left to right across the frame starting at 0.
You may need to adjust these settings if you are
a TFT display or adding an extender.
The settings also determine how the Bay Server control system is named; this will help locate its IP address
should you need to perform a
.
Bay Server
Location
Function
Address
Control System Naming
Central GUI
8
0
"nickname"_GUI_0
Channel Bay
0
0, 2, 4, etc.
"nickname"_BAY_0, BAY_1, etc.
Note that for channel bays, address 0 is the left-most bay.
The example below shows the settings for a 32+16C+16 frame:
Adding an Extender Bay
If an extender is added to the left of the main frame, then the addresses of each main frame bay must be shifted
upwards.
If the extender is added to the right, then its address can be counted upwards from the main frame.