crystal User Manual
Version: 6.6.0/2
383/459
20. Networking Options
20.2
Remote Control from Playout Systems (RAS)
"System -> Definition -> Parameter = OnAirControl"
This branch of the 'Tree Definition' provides 64 inputs and outputs to control or respond to functions within an
external Radio Automation System (RAS).
Select "
System
->
Definition
" in 'Tree Definition' and the
OAC
tab to access the options:
Parameter
OnAirControl – reference name for the element.
TCP-Mode
Check this box to enable RAS (Radio Automation System) control over TCP/IP.
OAC GPO 1 to 64
Assign a control signal (e.g. MF Key) to each of the OAC GPOs.
This allows functions within the system to remotely control functions within the Radio
Automation System.
Aux No. Musik
Enter the aux bus number dedicated to the Music signal (for RAS control).
Aux No. Speech
Enter the aux bus number dedicated to the Speech signal (for RAS control).
The following control outputs appear in the 'Tree Selection', under “Logic -> Definition -> Parameter
OnAirControl”. They can be used to signal when a RAS function is active.
OAC GPI 1 to 64
Active when the allocated RAS function is active.