crystal User Manual
Version: 6.6.0/2
245/459
13. Intercom
13.4
InterCom Software
The
InterCom
software is used to program the talkback buttons and then transfer the InterCom configuration to
each system. Four steps are required:
1.
Create a new configuration.
2.
Add the InterCom stations. This step names each station and defines the number of talkback buttons.
3.
Define the InterCom content. Each button can call another InterCom station, answer any incoming call,
call a group of InterCom stations or perform no function.
4.
Save and transfer the InterCom configuration to the system.
crystal
and
sapphire compact
systems support
Intercom Net Client
elements only. This means that they
do not require a separate InterCom configuration; the InterCom configuration must be stored on the server's
system.
13.4.1
System Requirements
InterCom PC
To install and run InterCom, your computer
MUST
meet or exceed the following requirements:
·
Operating System: Windows XP Professional SP3 or Windows 7 Ultimate. Note that Windows 10 LTSB
(Long Term Servicing Branch) for Enterprise installations is not supported.
·
Processor: Intel™ Core i3 530 (or higher equivalent processor).
·
Random access memory (RAM): 2GB
·
Ethernet interface: 100MBit/s
·
CAN over Ethernet service running (see
).
Lawo OnAir System
The Lawo OnAir system
MUST
be running OS Version 3.2 software or higher.
You can check the OS version using the
If the OS-Version is lower than 3.2, please contact your local Lawo representative or email
crystal
and
sapphire compact
systems support
Intercom Net Client
elements only and therefore do not
require a separate InterCom configuration.
Network
You should connect the
InterCom
PC to the Master Board’s Ethernet port either directly or via a network switch.
Do NOT
use an Ethernet hub as this will interrupt the data stream. See Wiring: CONTROL Network.