Lawler 3000 Installation & Maintenance Manual Download Page 1

temperedwater.com

5330 East 25th St.

Indianapolis, IN 46218
Phone (317) 261-1212

Fax (317) 261-1208

INSTALLATION &

MAINTENANCE MANUAL

Design and specifications subject to change without notice.

Please refer to 

temperedwater.com

 to ensure most

current data sheet and other design solutions. 

temperedwater.com/patents

M 3000 E

ASSE 1070 Approved
ASSE Lead Free Certified

Certified to CSA B125.3

NOTICE!

 

No mixing valve will work satisfactorily if improperly installed. We suggest, therefore, that you read 

these instructions carefully before installing and follow directions as outlined. Handle the mixing valve with care.

CAUTION: When maintaining and adjusting the 

mixing valve, all fixtures should be isolated from 

use. Lawler Manufacturing Co., Inc. recommends 

that you work safely at all times and in a manner 

consistent with the OSHA Lock/Tagout standard,  

29 CFR 1910.147 and other applicable standards.

This installation & maintenance manual covers all 

configurations of the Model 3000.

Model 3000

Thermostatic Shower Valve

3500 less stop & check valves

72047_3500-50_STD_DRW_NODIMS.pdf

B

A

A

D

C

E

DIMENSIONS

  Valve Number 

A  N.P.T.  B  N.P.T. 

E

 

3500

 

1/2” 

1/2” 

7-1/2” 

5-1/8” 

3-1/2”

Dimensions are for reference purposes only. For rough-in dimensions 
please refer to Lawler’s Revit/BIM models found at temperedwater.com.

3800 less stop & check valves

73047_3800-50_STD_DRW_NODIMS.pdf

B

A

A

C

D

DIMENSIONS

  Valve Number 

A  N.P.T. 

B  N.P.T. 

D

 

3800

 

1/2” 

1/2” 

3-1/2” 

4”

Dimensions are for reference purposes only. For rough-in dimensions 
please refer to Lawler’s Revit/BIM models found at temperedwater.com.

3900 less stop & check valves

74147_3900-50_STD_DRW_NODIMS.pdf

B

A

A

C

D

DIMENSIONS

  Valve Number 

A  N.P.T. 

B  N.P.T. 

D

 

3900

 

1/2” 

1/2” 

10-1/2” 

5-1/2”

Dimensions are for reference purposes only. For rough-in dimensions 
please refer to Lawler’s Revit/BIM models found at temperedwater.com.

Summary of Contents for 3000

Page 1: ...ock Tagout standard 29 CFR 1910 147 and other applicable standards This installation maintenance manual covers all configurations of the Model 3000 Model 3000 Thermostatic Shower Valve 3500 less stop check valves 72047_3500 50_STD_DRW_NODIMS pdf B A A D C E DIMENSIONS Valve Number A N P T B N P T C D E 3500 1 2 1 2 7 1 2 5 1 8 3 1 2 Dimensions are for reference purposes only For rough in dimension...

Page 2: ...crews 9 Turn mixing valve handle toward cold position until it forces cover off valve body The thermostat can now be examined Mixing valve Valve is carefully assembled and tested at the factory and set to deliver water at any temperature between full cold and 110 F Failure of the cold water supply will cause the hot water seat to close The label on the valve cover is marked HOT COLD so that the ha...

Page 3: ...b Assembly consisting of parts s 16 17 18 19 and 20 is factory pre set with Liner 21 as a single unit Use only genuine factory parts for replacement of seat washers thickness will affect the operation of the mixing valve When in Need of Information When writing the factory or one of its representatives in regard to a mixing valve be sure to give the number appearing on the name plate fastened to t...

Page 4: ...asher 4 Stem 5 Spring 6 Nose 7 Washer 8 Body 1 2 3 4 5 6 7 8 Kit I 1 2 Angled Stop Check with Strainer Part No 70484 00 Repair Kit 79922 02 Item Description 1 Adjustment Stem 2 O Ring Seal 3 Bonnet 4 Spring 5 Strainer Plug 6 O Ring Gasket 7 Strainer 8 Strainer Disc Holder 9A Body Right Hand 9B Body Left Hand 10 O Ring Disc Kit J 1 2 Stop Check Part No 6839 01 Repair Kit 79905 02 4 10 1 3 2 8 5 7 6...

Reviews: