User’s Manual & 

Operating Instructions

CONSUMER: READ AND SAVE THESE INSTRUCTIONS

GENERAL HAZARD WARNING:

READ AND UNDERSTAND ALL OF THE INSTRUCTIONS IN THIS MANUAL 

BEFORE ASSEMBLING, STARTING, OR SERVICING THE HEATER. 

Be sure to comply with the 

instructions and warnings provided with this heater. Failure to comply can result in fire or explosion 

that can cause property loss, bodily injury, or loss of life. Only persons who can follow and 

understand these instructions should operate or service this heater. 

DANGER

NOT FOR USE IN RESIDENTIAL LIVING AREAS OR IN ENCLOSED SPACES 

WITHOUT ADEQUATE VENTILATION. INDOOR USE PERMITTED ONLY FOR 

THE TEMPORARY HEATING OF BUILDINGS OR STRUCTURES UNDER CONSTRUCTION, 

ALTERATION OR REPAIR. 

This is an unvented portable heater that uses air (Oxygen) from within 

the area in which it is used.  Failure to provide adequate combustion and ventilation air will result in 

asphyxiation, carbon monoxide poisoning, bodily injury or death. Refer to “Ventilation” on Page 7.

DANGER

This appliance shall be installed in accordance with the rules in force, 

and used only in sufficiently ventilated space. Consult instructions before 

installation and use of this appliance. 

WARNING

FACTORY ID: 500

LWKF-400

FF70

FF125

FF175

Summary of Contents for FF125

Page 1: ...ions should operate or service this heater DANGER NOT FOR USE IN RESIDENTIAL LIVING AREAS OR IN ENCLOSED SPACES WITHOUT ADEQUATE VENTILATION INDOOR USE PERMITTED ONLY FOR THE TEMPORARY HEATING OF BUIL...

Page 2: ...NSTRUCTIONS Failure to comply with the precautions and instructions provided with this heater can result in death serious bodily injury property loss or damage from the hazards of fire soot production...

Page 3: ...every 100 000 Btu Hr heater rating Refer to Ventilation on page 7 for further instructions ALWAYS use only the electrical power voltage and frequency specified on the model plate of the heater ALWAYS...

Page 4: ...z 240VAC 50Hz 240VAC 50Hz 240VAC 50Hz Phase Single Single Single Single Single Specifications subject to change without notice Hot Air Outlet Upper Shell Lower Shell Fuel Tank Fan Guard Pressure Gauge...

Page 5: ...ssembly 1 Align holes in the upper housing with the 2 holes in the handle as shown in Figure 3 2 Insert screws and tighten firmly Cord Wrap Assembly 1 Insert tabs into square slots in shell support an...

Page 6: ...n Tools Needed Phillips Head Screw Driver 8 mm open end wrench 19 mm open end wrench Assembly Instructions Models FF125 FF175 FF215 What s In The Box Wheels 2 Axle Nuts 2 Spacers 2 Front Handle Axle R...

Page 7: ...ure 7 Attach rear handle with 2 long screws 50 mm and 2 nuts through the third hole from the rear of the heater on either side See Figure 6 8 Tilt the heater up gently so it is resting on the front ha...

Page 8: ...store kerosene in a red container Red is associated with gasoline Ventilation Risk of indoor air pollution and Carbon Monoxide Poisoning Use heater only in well ventilated areas Refer to Safety Infor...

Page 9: ...rature setting The thermostat set range is from 4 5 C to 43 4 C 3 Move power switch to On position The power indicator light and room temperature display will illuminate and heater will ignite See Fig...

Page 10: ...NOT TAMPER WITH THE UNIT HAVE A COMPETENT SERVICEMAN MAKE ANY NECESSARY ADJUSTMENT OR REPAIRS Use only original equipment parts The use of alternate or third party components can cause unsafe operatin...

Page 11: ...minated fuel could make cleaning the fuel filter necessary immediately NOTE To remove the filter from models 45 FF70 turn filter 90 clockwise To remove the filter from models 125 175 FF215 turn filter...

Page 12: ...0 NOZZLES Nozzles should be cleaned or replaced at least once per heating season Contaminated fuel could make this necessary immediately To clean dirt from nozzle blow compressed air through nozzle fr...

Page 13: ...plug 4 Clean replace fuel filter 5 Clean replace nozzle 6 Rinse fuel tank with clean fresh paraffin 7 Inspect all electrical connections See wiring diagrams on page 11 8 Re attach ignitor wire to spa...

Page 14: ...TO A POWER SOURCE 2020 Lavorwash Kerosene Forced Air Heater User s Manual 24 17 10 14 11 13 8 12 9 30 26 3 16 17 2 1 4 6 7 22 18 19 21 43 44 21 21 30 20 15 41 33 35 36 29 28 5 32 31 25 27 38 37 39 34...

Page 15: ...200 16 Spark Plug Kit 70 052 0100 70 052 0100 70 052 0100 70 052 0100 17 Motor 70 021 0501 01 04 70 104520034 70 021 0501 01 04 70 104520034 18 Pump Body 70 020 0101 01 01 70 004510021 70 020 0101 01...

Page 16: ...r 70 020 0102 01 01 70 004510023 70 020 0102 01 01 70 004510023 21 Filter Kit 70 054 0100 70 054 0100 70 054 0100 70 054 0100 22 End Filter Cover 70 020 0103 01 02 70 007010022 70 020 0103 01 02 70 00...

Page 17: ...0 0401 01 01 70 019010089 19 Rotor Kit 70 022 0200 70 022 0200 20 End Pump Cover 70 020 0102 01 01 70 004510023 21 Filter Kit 70 054 0100 70 054 0100 22 End Filter Cover 70 020 0103 01 02 70 007010022...

Page 18: ..._______________________________________________ ____________________________________________________________ ____________________________________________________________ ______________________________...

Reviews: