11
Control Unit
The R-
CAM XLT Control Unit is a lightweight portable, hard case that houses the 9” LCD Monitor
Video display with DVR and all the necessary electronics, to control and operate the Camera in
a lightweight, portable, hard cover, carrying / storage case.
The front panel controls on the Control Unit are shown in Figure 9.
12 VDC power is supplied to the control unit from the DW-1500/DW-2000 Winch 12 VDC
output.
The ON-OFF Switch (Figure 9 Item 5) routes power to the Camera and the Camera LED lighting
when switched to the ON position.
The FORWARD-REVERSE Switch (Figure 9 Item 6)
rotates the Camera’s Side
-View and Down-
View images, and is spring loaded to the STOP (center) position when released.
The VIEW-LIGHT Switch (Figure 9 Item 7) controls the image and light to be viewed on the LCD
Monitor, and is spring loaded to the center position when released. Pressing VIEW toggles
between “DOWN VIEW” and “SIDE VIEW” on the Monitor. Pressing LIGHT cycle
s through 5
preset light intensities or levels. The “DOWN VIEW” light intensity is independent of the “SIDE
VIEW” light intensity and do not have to match.
The CLEAR Switch (Figure 9 Item 8) is used to set the depth counter to zero (000.00f) after
positioning the Camera near the top of the well prior to the start of the survey.
NOTE: THE DW-1500/DW-2000 WINCH MUST BE SUPPLIED BY EITHER 115 VAC OR 220
VAC 60Hz/50 Hz. WINCH INPUT POWER VOLTAGE MUST BE SPECIFIED AT TIME OF ORDER.
NOTE: The REEL CONTROL functions of the Control Unit will NOT operate the Winch Motor
Control Functions and WILL disrupt power to the Camera if switched ON.
For DVR set-up and connections, see DVR GUIDE on page 12