- 37 -
-
The CYCLE END contact is closed;
-
The display shows the weight preceded by the letter
;
-
Only if
=
: batching data (with date and time) are printed.
-
Only if
=
: consumption is stored.
11.
At the beginning of the product extraction, if the
time is set and the product is not extracted
by at least 20 divisions within this interval of time, the
alarm message will be displayed.
12.
The system ends the batching (opening of the CYCLE END contact) only after verifying that:
-
The weight is lower than the minimum weight (
);
-
The safe emptying time has elapsed (
);
13.
Only if
=
: the instrument waits for data recording on PC, before being available for a
new batching.
If several batching cycles have been set the instrument starts a new cycle.
BATCHING START FROM EXTERNAL CONTACT
It is possible to select the required formula via an external selector switch. After selecting the
formula, close the START external contact for at least 0.5 seconds and, verified the conditions
indicated in section
BATCHING
, the instrument will perform the selected formula batching.
If there is no the formula selection switch (E/EC options), the latest formula entered via the keypad
will be batched, or it’s possible to set the required formula in the following menu: press the MENU
key for 3 seconds,
will be displayed, set the required formula number using the arrow keys
and confirm with ENTER. At batching start, the set formula will be performed. If 00 is set, the latest
formula set via keypad will be recalled.
If at the end of the batching, the START contact is closed, the same batching
sequence is repeated.
DISPLAYING DURING BATCHING
During the batching the display shows the weight preceded by the letter
.
By pressing ▲ the formula number is displayed, by pressing it again the number of running cycle is
displayed.
BATCHING STOP
-
Open the START contact and close the STOP contact to stop the batching. If the START contact
is closed, the
alarm is displayed.